DONNING
Do not use the respirator unless the regulator is con-
nected properly. A regulator that is not installed cor-
rectly can separate from the facepiece unexpectedly.
Return the respirator to an MSA trained or certified
repairperson to correct the condition. Failure to follow
this precaution can result in serious personal injury or
death.
5. Inhale sharply to start the air flow.
a. Check the bypass again by turning the red knob
counter-clockwise until you feel increased air flow.
Close the bypass.
There must be a continuous flow of air when the
bypass knob is opened. If not, do not use the appara-
tus. The SCBA must be checked and corrected for
proper operation by an MSA trained or certified repair-
person before using it. Failure to follow this precaution
may result in serious personal injury or death.
Note:
If the air mask passes all tests, the unit is ready to
use. Remember, you must perform these tests every time
before you enter the hazardous atmosphere. If the unit
fails to meet any of the tests, the condition(s) must be
corrected before using the apparatus.
PRECAUTIONS DURING USE
•
Be sure the NightFighter Heads-Up Display System is
in Continuous Operations Mode.
•
Periodically check the pressure on the NightFighter
Heads-Up Display System.
•
When the NightFighter Heads-Up Display System
starts flashing a Red LED, immediately return to fresh
air.
Note:
Air mask service life is reduced greatly when the
bypass is used.
•
Reduced air flow:
Immediately
open the
bypass.
Immediately
return to fresh
air.
•
Air mask free-flows:
Immediately
return to fresh
air.
•
NightFighter Heads-Up
Immediately
return to fresh
Display System flashes
air.
a return to Red LED:
INSTALLING SLIDE MASK MOUNTED REGULATOR
1. Grasp regulator and orient regulator so that red
bypass knob is pointing to the right and slide button is
on top.
2. Slide regulator onto rail (fast track) of facepiece cover.
Slide regulator down the rail cover until regulator
stops.
3. Insert regulator into facepiece adapter by pushing
inward.
4. Ensure the regulator locks into facepiece.
5. Check proper engagement by pulling on the regulator
to ensure regulator is securely attached to facepiece.
Do not use the respirator unless the regulator is con-
nected properly. A regulator that is not installed cor-
rectly can separate from the facepiece unexpectedly.
Return the respirator to an MSA trained or certified
repairperson to correct the condition. Failure to follow
this precaution can result in serious personal injury or
death.
1. Inhale sharply to start the air flow.
a. Check the bypass again by turning the red knob
counter-clockwise until you feel increased air flow.
Close the bypass.
There must be a continuous flow of air when the
bypass knob is opened. If not, do not use the appara-
tus. The respirator must be checked and the condition
corrected by an MSA trained or certified repairperson
before using it. Failure to follow this precaution may
result in serious personal injury or death.
Note:
If the air mask passes all tests, the unit is ready to
use. Remember, you must perform these tests every time
before you enter the hazardous atmosphere. If the unit
fails to meet any of the tests, the condition(s) must be
corrected before using the apparatus.
12
TAL 601 (L) Rev. 5 - 10041214
WARNING
WARNING
WARNING
WARNING