Maintenance
EVOLUTION 6000 Thermal Imaging Camera
39
US
5
Maintenance
The product should be regularly checked and serviced by trained personnel. A record must be
kept of the periodic inspection and maintenance. Always use original parts from MSA.
Repairs and maintenance must be carried out only by authorized MSA service centers.
Changes and modifications are not permitted and may result in voiding the approval.
MSA is liable only for maintenance and repairs carried out by MSA.
The camera must be stored in a dry, protected location between -40°C and +70°C (-40°F and 158°F).
5.1
Before Each Use
Each time the camera is used, a visual inspection must be performed following the criteria below:
-
Check for housing damage due to mechanical, chemical or thermal loads.
-
Inspect the camera for loose or missing screws, O-rings or seals.
-
Check for cracks and other damage to the display. Verify that all device labels are attached.
5.2
After Each Use
(1)
Carefully clean all outside surfaces [camera housing including the handles, lens, display win-
dow and carrying devices] with warm water and a gentle cleaning agent.
(2)
Carefully dry using a soft, lint-free cloth. Avoid scratching the display window.
(3)
All switches, buttons, battery compartment locks and lids must be inspected for dirt and
cleaned using a soft, lint-free cloth and brush if necessary.
WARNING
Do not open the thermal imaging camera housing as there are no user serviceable parts inside.
Only authorized personnel may service the unit. FAILURE TO FOLLOW THE ABOVE
WARNING CAN RESULT IN SERIOUS PERSONAL INJURY OR DEATH.
NOTICE
Do not use any solvents or thinners to clean the camera as they may attack the camera housing
materials. Do not use abrasive cleaners or cloths for cleaning the camera as these may also
damage the camera.