background image

URC ASSEMBLY OPERATION

The URC (Universal Rescue Connection) Assembly is a
male quick-fill inlet for use by Rapid Intervention Crews
for emergency filling operations. The system also includes
an automatically resetting pressure relief valve. The SCBA
can also be equipped with a shoulder-mounted Quick-Fill
System, unless using a 3000psi URC Assembly, the
3000psi URC Assembly cannot be used with Quick-Fill
System.

The URC Assembly is not to be used as a "Buddy
Breather" such that two (2) users are sharing the air
supplied by one (1) approved SCBA cylinder simulta-
neously; doing so will void NIOSH approval. Failure to
follow the above warnings may result in serious per-
sonal injury or death.

The URC Assembly must be used by trained Rapid
Intervention Crews only using procedures developed
for rapid intervention. Improper use can result in seri-
ous personal injury or death.

Note:

The URC Assembly may be used for transfill opera-

tions as described in this manual. Standard operating pro-
cedures should be developed for use of the URC
Assembly or Quick-Fill System.

An air mask using the 3000psig URC Assembly with-
out Quick-Fill System can receive (be a Receiver)
cylinder pressure through the 3000psig URC
Assembly. Do not use air mask with Quick-Fill System
and 3000psig URC Assembly on the same air mask.
Air mask with Quick-Fill System and 3000psig URC
Assembly on same air mask will not allow the relief
valve in the 3000psig URC Assembly to open as
designed. Failure to follow the above warnings may
result in serious personal injury or death.

The URC Assembly must be used only by qualified,
trained personnel who have carefully read and understood
these instructions, cautions, and warnings. NIOSH
approvals of SCBA from MSA are maintained while trans-
filling air ONLY if appropriate Quick-Fill hose assemblies
from MSA are used. URC Assembly or Quick-Fill hose
assemblies and fittings are rated for a maximum working
pressure of 4500psig.

NIOSH approval is maintained only when using the follow-
ing hose assemblies:
485331, 802687, 802688, 802689, 802690, and 48332, for
filling cylinders in IDLH atmospheres.

DO NOT Transfill (be a Donor) using a 3000psi URC
Assembly. The 3000psi URC Assembly has a check
valve that does not allow cylinders to Transfill (be a
Donor). Using the 3000psi URC Assembly to fill cylin-
ders, the cylinder can only be filled to 2216psig. If the
pressure exceeds 2216psig a relief valve in the URC
Assembly will vent at approximately 2525psig or as
low as 2400psig. A 3000psig cylinder can only be filled
to 3000psig by using a secondary air source; the
3000psi URC Assembly cannot be used for filling a
3000psig cylinder. Failure to follow the above warnings
may result in serious personal injury or death.

For filling operations using the URC Assembly, do not
use any transfilling hose assembly or fittings other
than those supplied by MSA specifically for the URC
Assembly or Quick-Fill System. Use of any other
transfilling hose assembly, fitting, or cylinder may
result in serious personal injury or death, and will void
NIOSH approval. Failure to follow the above warning
may result in serious personal injury or death.

DO NOT lubricate the URC Assembly fittings. Do not
permit oil, grease, or other contaminants to come in
contact with the Quick-Fill fittings. The Quick-Fill hose
assemblies and fittings are designed to be used with
Quality Verification Level (Grade) D or better air as
defined by ANSI/CGA G-7.1. TRANSFILLING AIR FROM
A SECONDARY AIR SOURCE. Failure to follow the
above warnings may result in serious personal injury
or death.

A secondary air source stores compressed breathing air
until needed to refill SCBA air cylinders. Secondary air
source pressure must be greater than air mask cylinder
pressure. Examples of air sources include: cascade air
cylinder refilling systems; high pressure compressor sys-
tems with a fixed reservoir; and an SCBA air cylinder
which is not installed on an SCBA.

DO NOT connect a High Pressure SCBA to a sec-
ondary air source with a pressure greater than
4500psig. The high pressure air mask is rated for a
maximum working pressure of 4500psig. Failure to fol-
low the above warnings may result in serious personal
injury or death.

21

TAL 709 (L) Rev. 4 - 10058881

Summary of Contents for ICM Tx

Page 1: ...Display System which integrates with the SCBA These instructions in addition to the instructions supplied with the SCBA must be carefully read and followed by all persons who use or maintain this prod...

Page 2: ...epiece Note The NightFighter Heads Up Display can only be used with an Ultra Elite Facepiece 2 The NightFighter Heads Up Display consists of three 3 separate assemblies Bracket assembly attached to an...

Page 3: ...nation of batteries from dif ferent manufacturers will affect the performance of unit and void the Intrinsic Safety Approval Intrinsically Safe Rating The NightFighter Heads Up Display System and ICM...

Page 4: ...4 TAL 709 L Rev 4 10058881 NOTES...

Page 5: ...he facepiece which displays the air cylinder pressure in one quarter cylinder increments by an LED light pattern See chart 1 Assembly of Receiver to Facepiece Bracket With the facepiece laying on its...

Page 6: ...6 TAL 709 L Rev 4 10058881 NOTES...

Page 7: ...m the unit o The center lighted ALARM button green red acti vates the full alarm mode with or without air pres sure o The top MODE button green will refresh the receiv er display set the receiver to c...

Page 8: ...8 TAL 709 L Rev 4 10058881 NOTES...

Page 9: ...Pressure Full Alarm with or without Pressure Deactivation of Full Alarm Deactivation of PreAlarm with Shake or move Unit Low Battery Thermal Alarm Activation see Thermal Alarm Activation Curve Redunda...

Page 10: ...trinsic Safety Approval is void Failure to follow this warning can result in serious personal injury or death Before using the ID tag inspect for damage or cracks in the case If damage is found discar...

Page 11: ...he bypass valve on the second stage regulator to bleed off pressure until the ICM Tx Unit pressure reading drops below the following values a 530psig approximately 2216psi system b 750psig approximate...

Page 12: ...NOTES 12 TAL 709 L Rev 4 10058881...

Page 13: ...injury or death Actual time remaining may be less than the calculated time displayed Increases in breathing rate may reduce remaining time more than expected Use time indica tor as general guide only...

Page 14: ...sure to tighten the battery cover screws enough to provide adequate compression on the battery cover gasket to prevent dirt and moisture from entering the battery compart ment A torque of 6 in lbs is...

Page 15: ...for missing screws or loose covers c Check for signs of leaking covers or water retention in the case d Check rubber cover for damage e Check for damaged or missing buttons on the unit f Check for any...

Page 16: ...cover 4 Before replacing the battery cover be sure that the rubber cover on the ICM Tx Unit is properly engaged with the plastic housing The rubber cover has barbs that hold it firmly against the plas...

Page 17: ...transfilling hose assembly or fittings other than those supplied by MSA specifically for the Quick Fill System Use of any other transfilling hose assembly and or fitting may result in serious personal...

Page 18: ...System hose to the SCBA c Remove the rubber dust cap from the male inlet fit ting on the SCBA Be sure that the cylinder valve is fully opened d Remove the rubber dust cap from the female fitting on th...

Page 19: ...he male Quick Fill System fitting d Push the female fittings on to the male fittings until they click in place Pull on the hose to be sure it snapped in place If serious leakage is noticed from either...

Page 20: ...NOTES 20 TAL 709 L Rev 4 10058881...

Page 21: ...emblies 485331 802687 802688 802689 802690 and 48332 for filling cylinders in IDLH atmospheres DO NOT Transfill be a Donor using a 3000psi URC Assembly The 3000psi URC Assembly has a check valve that...

Page 22: ...either female fitting or along the hose depressurize the hose and correct the prob lem Such leakage can result in increased fill time 2 To attach the Quick Fill System hose to the URC Assembly a Remo...

Page 23: ...c Quickly replace the protective dust cap on the URC Assembly male regulator fitting This will form a redundant seal d Open the cylinder valve and return to fresh air immediately The dust cover preven...

Page 24: ...eration and instructions manual PN 10023638 for additional war ranty information For a copy of the complete warranty or for information on submitting a warranty claim write to MSA Customer Service Dep...