The TLV of the mixture (T
Mixture
) is found by using the following formula where T
1
, T
2
, T
3
, . . . are the individual contaminant
TLVs and C
1
, C
2
, C
3
, . . . are the individual contaminant concentrations:
Only use these equations if the contaminants present are actually mixed. Some substances do not mix and may be present
separately, for example, in pockets or at different levels. In that case, the lowest TLV of the substances present must be used
to determine the appropriate respirator category for protection against all contaminants present.
See MSA’s
Response® Respirator Guide
for additional information.
2.4.2 Technical Information
Airflow: When used with the MSA battery pack, the OptimAir TL PAPR provides a constant filtered airflow of a minimum of
170 lpm to the hood, and 115 lpm to the tight fitting facepiece.
2.4.3 Battery Pack
Rechargeable 12 volt (nominal) nickel-metal hydride (NiMH) battery pack. (Standard Battery) Rechargeable 14.4 volt (nominal)
lithium ion (Li-Ion) battery pack. (Extended Life Battery)
2.4.4 Contents
The OptimAir TL PAPR kit is shipped with the components listed.
NOTE:
Upon receipt of the PAPR kit, inspect the contents for shipping damage and ensure all components are present.
Loose Fitting Kit with Standard Battery
•
OptimAir TL PAPR Blower Assembly
•
Breathing Tube Assembly - Hood
•
Decon Belt Assembly
•
Standard Battery Pack
•
Standard Battery Charger
•
User’s Instruction Manual
Loose Fitting Kit with Extended Life Battery
•
OptimAir TL PAPR Blower Assembly
•
Breathing Tube Assembly - Hood
•
Decon Belt Assembly
•
Extended Life Battery Pack
•
Extended Life Battery Charger
•
User's Instruction Manual