Appendix: HART Specific Information
10 Appendix: HART Specific Information
The TG5000 Gas Monitor is available with an optional HART (Highway Addressable Remote
Transducer) output communications protocol. With this option, the TG5000 complies with
HART Protocol Revision 7.
All available status bytes are defined in the X5000 HART Specification found on the product CD.
Refer to that document for complete HART command and status definitions. Use the HART digital
interface to query the unit to provide additional troubleshooting information.
Manufacturer Name
Mine Safety Appliances, Inc
(MSA)
Model Name
TG5000
HART ID Code
227 (0xE3)
Device Type Code 46 (0x2E)
HART Protocol Revision
7
Device Revision
1
Number of Device Variables 2
Physical Layers Supported FSK
Tab. 22 Device Identification