6
B-1. RCD Test
WARNING: RISK OF ELECTRIC SHOCK. The RCD plug must be tested before each use.
WARNING:
Insert the RCD plug into a residual current device (RCD) protected power receptacle only.
WARNING:
Before inserting the plug into a power receptacle, make sure the current rate of the power receptacle
and the fixed wiring are suitable for the Spa. Contact a qualified electrician if you cannot verify.
1. Insert the plug into the power receptacle. (1)
2. Press the “RESET” button. The indicator area should turn red. (2)
3. Then press the “TEST” button. The indicator area should disappear. (3)
WARNING: Do not use if above test fails.
4. Finally, press the “RESET” button again. The indicator area should turn red. The spa is ready for use. (4)
B-2. PRCD Test
Mspa comes with a PRCD plug for Switzerland and Australia standard, please watch below diagram flow for
plug test and use.
C. Assembly
a) Unfold the Spa pool from the packaging. Take out the spa pool body, cover and temp barrier mat. Make sure spa
and cover top are right side up. Put temp barrier mat under the spa tub.
Note: B-100 includes a side bar, which needs to be placed before filling water to the tub. The side bar helps
keeping the spa pool in its proper shape after filling.
For B-091 , please spread out the square ground cloth first, the straps attached on ground cloth is for
connection with top lid. Then set up spa pool on it.
Heat preservation mat can prevent heat loss from bottom of the unit and provide better heat preservation
with together of the inflatable bladder being used.
It is possible to install and leave the spa tub outside at a temperature below 4°C, but only if the water temperature
inside the pool is higher than 4°C and water in pipe is not frozen. The spa tub can be operated in cold weather with
temperature down to maximum -10°C if the unit is properly set up and no frozen water inside the control box, pipes
or spa pool. It’s helpful to put temp barrier mat in between the spa pool and the ground. Similar mat which is made of
foam material or other materials with temp barrier function can also be used.
Don’t install Mspa onto the lawn as grass may cause air pump damped and rusted which could result the air pump
works improperly and will void your warranty.
Press the “RESET” button. The indicator
area should turn red.
Then press the “TEST” button. The
indicator area should disappear.
WARNING: Do not use if above test fails.
Finally, press the “RESET” button again.
The indicator area should turn red.
The spa is ready for use.
RESET
TEST
RESET
TEST
RESET
TEST
*
*
Summary of Contents for B- 131 Luxury Exotic