9
POWER PACK OPERATION
Warning: to avoid function failure and damage, please do not operate until spa is
filled
with water to the low water mark.
It is the responsibility of the spa owner to make sure the above installation conditions are met as well as to
follow the Safety and Warning Instructions. Any failure and damage, which may result from dry-run, water
spillage, excessive humidity, or structural loading will void the warranty.
Control panel:
2. “BUBBLE” Button: To activate Bubbling system,
which has a 20-minute auto shut off for 10 minutes
feature. The light of bubble Button displays green
when being activated.
NOTE: If it works more than 15 minutes and stop manually,
please wait more than 10 mintues to activate manually again.
3. “FILTER” Button: To activate Filtration system.
The light of “FIL
TER” button displays green when the filtration system is activated.
4. “HEATER” Button: To activate Heating and Filtration system at the same time.
(Filtration system cannot be turned off when heating)
5. “TEMPERATURE” Button: To set and display water temperature
6. “UP” Button: Increase temperature
7. “DOWN” Button: Lower temperatrure
1 0 0
1. “ON/OFF” Button: To activate power pack.
LED Display: Once powered-up, the LED displays the current water temperature automatically.
NOTE:
The setting temperature defaults to 38°C (100°F) when first plugged in.
NOTE:
Temperature adjustment ranges from 20°C (68°F) to 40°C (104°F).
Set your desired temperature by pressing “TEMPERATURE” Button.
Note:
In case when leaving spa under unattended working condition, you can press up “ ” &. down “ ”
buttons at the same time to lock the conttrol panel to avoid any misoperation by children. To press both
buttons at the same time again and after hearing sound of “DI”, it will be unlocked.
The light of the “HEATER” button displays red when the heating system is activated.
Note: It’
s normal that filtration system cannot be turned o
ff individually when heating system is working.
And filtration system can only be turned o
ff by pressing “HEATER” button but not “FILTER” button
The heater does not stop heating the Spa until the current water temperature reaches the setting
temperature. Then the “FILTER” button will be off and the light of “HEATER” button displays green.
After the current water temperature drops 2°C(4°F) below the set point temperature, the heating system
will restart and light turns into red. The “FILTER” button will be activated automatically at the same time.
The heat increase rate is maximumly 1.2 to 1.7°C(1-3°F) per hour.
Please note that the following conditions will lead to slow and even heating without heating phenomenon:
1. Environmental temperature lower than 10°C(50°F)
2. Outdoor wind force above Gentle breeze/F 3
3. Environmental temperature lower than 10°C(50°F) and wind power above Gentle breeze/F 3
4. Activate bubbling system when heating
5. Spa lid is not covered or improperly covered when heating
6. In order to conform to the safety regulations, MSpa control system uses double heating elements
technology. When heater functions are all on, only one heating element is working,
which is of 675W only
Meijer.com