2019 Premium Concept Elite Service Manual
Visit our website at: www.the-mspa.com
- 39 -
Chapter 7. Attachment
Premium Elite Delight Concept
Spa Check Flow
–E0-E1.pdf (Same as SS18 delight)
Premium Elite Delight Concept
Spa Check Flow
–heating failure.pdf (Same as SS18 delight)
Premium Elite Delight Concept
Spa Check Flow -NO DISPLAY.pdf (Same as SS18 delight)
SS19 spare parts list
EU/SW/UK version
2018 VS 2019 Premium Elite Concept parts differences:
PPT
Repairing video download link:
https://www.adrive.com/public/Mqvf8b/2019%20Elite%20Premium%20Concept
2019 Premium/Elite/Concept troubleshooting easy checking
Problem
Cause
Solution
No display on the
control panel
Power failure
Check power supply
PRCD is off
Reset PRCD by following PRCD testing section
PRCD is broken
Contact the local Mspa service center or partner for a
new replaced PRCD.
Press the reset button, still no display
on the panel
Contact the local Mspa service center or partner for a
new replaced panel.
Spa leaking
Spa inlet/outlet connection not
securely tight
Tighten the inlet and outlet connection by wrench tool.
Drainage valve is not closed
completely
Close the drainage valve. Contact the Mspa service
center or partner for a new liner replacement, if spa is
still leaking.
Water leaks from the spa pool body
Repair the leaking hole/spilt with the repair patch.
Aquaseal glue is recommended.
Ozonator failure
The water level is not at minimum
water line
Add more water to reach the minimum water line.
One-way valve blocked
Contact the Mspa service center or partner for warranty
repairing work.
Filter pump doesn't work
Refer to filter pump doesn't work section
No heating
properly
Temperature set too low.
Set a higher temperature.
Dirty filter cartridge
Clean or replace the filter cartridge
Heating element failed
Contact the Mspa service center or partner for warranty
repairing work.
Low water level
Add more water to reach the minimum water line.
Control panel failure
Contact the Mspa service center or partner for warranty
repairing work.
Bubble air blower
does not work
Bubble motor failure
Contact the Mspa service center or partner for warranty
repairing work.