Make sure to set up the spa on a firm, level and smooth surface that is strong enough to support the full
weight of the filled spa and maximum occupants.
Do not set up the spa on grass or dirt, as this increases the amount of debris entering the spa, and
damage the spa floor.
Do not leave the spa tub exposed to direct sun light for extend period of time.
It is the possible to install and leave the spa outside at a temperature not lower than 4°C (39°F) and the
water inside the circulation system, pump, pipe are not frozen. Put a Heat Preservation Mat or the Electric
Heating Mat (*Optional) in between the spa bottom and the ground to prevent heat loss from the bottom of
the spa and to provide better heat retention.
Additional requirements for outdoor installation
Plug the machine into the mains.
Press the
RESET
button on the RCD. The indicator turns red.
Press the
TEST
button on the RCD. The RCD indicator should shut off. If the RCD indicator does not turn off,
the RCD is faulty.
Do not use the spa. Contact a qualified electrician to correct the fault.
Press the
RESET
button on the RCD again. The indicator should turn red. If yes, the spa is ready for use.
1.
2.
3.
4.
RCD or PRCD Testing
Risk of electric shock: This product is provided with a RCD located at the end of the power cord. The RCD
must tested before each use. Do not use the spa if the RCD does not function properly. Disconnect the
power cord until the fault has been identified and corrected. Contact a licensed electrician to correct the
fault. There are no serviceable parts in side the RCD. Opening the RCD will void the warranty.
PRCD
For spa models of Switzerland markets, test the PRCD using the above testing steps.
1.
2.
RESET
3.
TEST
4.
Indicator area
!
WARNING
1.
2.
RESET
3.
TEST
RESET
T
RESET
T