background image

 

 

© MSR Electronics GmbH, 2022-02-22. All rights reserved. 

 

 

 

 

 

 

   

  

12

 

MSR Electronics GmbH • Mettlenstrasse 6 • CH-8472 Seuzach • Switzerland 

Phone. +41 52 316 25 55 • info@msr.ch • www.msr.ch • www.datalogger.shop 

 

STOP Data Logger 

 
To stop recording, press the «STOP» button continuously for 5 seconds until the red LED is ON.  
Note: Logger will be automatically STOPPED after 10 seconds when connected with the USB port of a PC. 
 

Report Generation 

 
MSR BudgetLine data loggers are available with integrated USB 2.0 A-Type plug. Hence, no additional hardware or cable is required to connect the logger 
with the PC. After stopping, when the logger is connected for the first time to the USB port of the computer, both LEDs (green & red) will start flashing to show 
the report generation is in process. Do not disconnect the logger until both LEDs (green and red) are ON continuously, which indicates the report is 
ready. Once the report is generated, whenever the logger is connected to the USB port of the computer, both LEDs (green & red) are ON continuously, which 
indicates the data logger is in stop mode and the report is already generated.  
 
Open data logger USB drive «PDF_Logger» that contains soft copy of the Quick Start Guide and the Calibration Certificate «CXXXXXXXXXX.pdf» and 
«UI4Report» – to get a report of the recorded readings in PDF / Excel / CSV formats.  

 

 

Summary of Contents for BudgetLine MSR63

Page 1: ...1 MSR Electronics GmbH Mettlenstrasse 6 CH 8472 Seuzach Switzerland Phone 41 52 316 25 55 info msr ch www msr ch www datalogger shop Manual MSR BudgetLine Data Loggers Reusable PDF data loggers for te...

Page 2: ...re data loggers and generate PDF Excel CSV reports of recorded readings from it Index Index 2 Requirements 4 Connect Data Logger 4 Configuring Data Logger 5 START Data Loggers MSR63 MSR64 7 START Data...

Page 3: ...data logger with external sensor 100 150 C MSR BudgetLine reusable low cost data loggers for transport and storage Reusable PDF data loggers for cost effective monitoring of temperature and humidity...

Page 4: ...a loggers are available with integrated USB 2 0 A Type plug Hence no additional hardware or cable is required to connect the logger with a PC Note The logger will be STOPPED automatically after 10 sec...

Page 5: ...e data logger folder PDF_LOGGER double click on UI4Report and click on Configuration window at the top on top Enter User Description Logger Interval Start After delay start time Alarm Limit Alarm Dela...

Page 6: ...nd then the green LED will be ON for a second indicating the configuration of the logger has completed successfully Check if configuration is completed successfully MSR BudgetLine loggers with display...

Page 7: ...o alarm condition recording alarm condition STOPPED low battery START the data logger Keep the START button pressed continuously for 5 seconds until the green LED flashes followed by a flashing of the...

Page 8: ...attery START the data logger Initially the current reading will be shown on the display before starting the data logger Keep the START button pressed continuously for 5 seconds to start the logger The...

Page 9: ...Logger is STARTED Logger is waiting till delay start time is completed Logger is in recording mode Logger is in STOP mode Press STOP button continuously for 5 seconds to stop the logger Low High Alar...

Page 10: ...ssing the START button for 5 seconds Waiting to START Press START button continuously for 5 seconds to start the logger Logger is STARTED Logger is waiting till delay start time is completed Logger is...

Page 11: ...and red will start flickering indicating the report generation of the recorded data is in process Do not disconnect the logger until both LEDs green and red are ON continuously which indicates the rep...

Page 12: ...the logger with the PC After stopping when the logger is connected for the first time to the USB port of the computer both LEDs green red will start flashing to show the report generation is in proce...

Page 13: ...ct your required report format PDF or Excel or CSV Report Action Default Location This will open a report of recorded readings in your selected format and save it in the default location C Users User...

Page 14: ...472 Seuzach Switzerland Phone 41 52 316 25 55 info msr ch www msr ch www datalogger shop Report Analysis Selected report format of recorded data will be automatically opened and saved at your selected...

Page 15: ...al Lo Volt is no longer visible Close the housing and screw the 4 screws back in Be careful not to overtighten the screws Troubleshooting If your MSR BudgetLine data logger no longer functions properl...