ENG

DANGER

This product makes chloroxygen chemical compounds generated electrolytically  

from a sodium chloride solution.

FIRST AID

Have this product label with you when calling a poison control center or doctor, or 

going for treatment.

If in Eyes:

 Hold eye open and rinse with water for 15-20 minutes. Remove contact 

lenses, if present, after 5 minutes. Continue rinsing eye. Call a poison control center or 

doctor for further treatment.

If Swallowed:

 Call a poison control center immediately for treatment advice. Have 

person sip a glass of water. Do not induce vomiting unless told to do so by a poison 

control center or doctor. Do not give anything by mouth to an unconscious person.

If on Skin:

 Take off contaminated clothing. Rinse skin immediately with plenty of water 

for 15-20 minutes. Call a poison control center or doctor for treatment advice.

PRECAUTIONARY STATEMENTS

Hazardous to Humans and Domestic Animals.

DANGER.

 Causes irreversible eye damage. Do not get in eyes or on clothing.  

Harmful if swallowed. May irritate skin.

ENVIRONMENTAL HAZARDS

This product is toxic to fish and other aquatic organisms.

PHYSICAL/CHEMICAL HAZARDS

Keep away from combustible, organic, or other readily oxidizable materials.

This product contains batteries. Batteries may explode or leak if disassembled, short-cir-

cuited, recharged, or disposed of in fire. Wipe battery terminals clean with a dry cloth 

before use. Do not store batteries in direct sunlight, high temperature, or high humidity.

READ, UNDERSTAND, AND FOLLOW ALL instructions and warnings in this manual 

before using this purifier.

Failure to follow all warnings and instructions may result in property damage, serious 

injury, or illness.

KEEP OUT OF REACH OF CHILDREN

MIOX is a high-tech municipal water treatment system shrunk to fit in your pocket.  

The purifier uses ordinary salt, a few drops of water, current from two CR123 Lithium 

batteries, and its proprietary technology to create a small batch of mixed oxidant  

solution. The treatment, when added to water and given a little time, transforms  

questionable water into drinkable water. Required treatment times vary for the  

different microorganisms: Viruses and Bacteria, 15 minutes; Giardia, 30 minutes; 

Cryptosporidium, 4 hours.

Combining salt and a small amount of  
water starts the purification process.

Electrical activation of the  
Salt Solution creates potent  
mixed oxidants.

Add the treatment solution to the  
contaminated water, wait a little time, and  
you will have drinkable water.

NaOCL

Kit Contents

 

MIOX

®

 Purifier

 

Rock Salt 

– 1 

oz. / 

28 g

 

CR123 Lithium 

Batteries – 

2 batteries

 

Safety Indicator 

Strips – 

50 strips

 

Instruction Manual

 

Storage Sack

Weight

 

Pen – 

3.5 oz. 

/ 99 

g

 

Kit – 

8 oz. 

/ 227 

g

Dimensions

 

Pen – 

7 x 

1 in. 

/ 18 

x 2.5 

cm

 

Kit – 

7 x 

4 x 

1.5 in. 

/ 18 

x 10 

x 4 

cm

Operating Temperature 

Range

 20-130 

F / 

-6-54 C

Water 

Resistance

 Up 

to 60 

ft. / 

18 m

Maximum Altitude

 60,000 

ft. / 

18 km

Batteries

 2 

x CR123 

Lithium camera 

batteries (6V 

total)

Battery 

Life*

 50 

± gal. 

/ 200 

± liters 

 

 

(depends on 

treatment use, 

water and 

battery 

quality)

Salt

 Granule, 

rock, or 

crystal 

salt (food-grade 

quality)

Salt Life*

 50 

± gal. 

/ 200 

± liters 

per 1 

oz. / 

28 g 

packet

One Full 

Salt Chamber

 20 

± treatments

Safety Indicator 

Strips

 50 

specifically for

mulated free-chlorine 

test strips

Safety Indicator 

Strips Life

 2 

years

*Product life 

ratings are 

best-case ratings. 

Worst-case 

life ratings 

are usually 

half of 

the 

listed life. 

Average 

life ratings 

fall between 

these two 

numbers.

Visit www

.msrgear.com 

for more 

information 

on MIOX 

and other 

MSR water 

 

treatment products.

Purifier

A har

mless white 

salt crust 

around the 

Salt Chamber 

may for

m but 

can be 

easily rinsed 

or wiped 

off.

Batteries

Buy inexpensive, 

replacement CR123 

batteries in 

bulk online 

at www

.surefire.com.

Use body 

heat to 

warm 

batteries in 

below freezing 

temperature.

To 

avoid corrosion, 

only handle 

batteries with 

dry 

hands in 

a dr

y environment.

Salt 

Use any 

food-grade salt 

in the 

purifier.

Use cr

ystals rather 

than granules 

for better 

water flow 

and longer 

use.

Safety Indicator 

Strips 

The Safety 

Indicator Strips 

do not 

need to 

be used 

every 

time water 

is treated.

Use the 

strips for 

these impor

tant times:

Use Safety 

Indicator Strips 

to lear

n the 

operation of 

the MIOX

®

 Purifier

. Use 

Safety Indicator 

Strips with 

new water 

sources to 

establish the 

correct number 

of treatments 

needed for 

that source. 

In most 

cases, 

one treatment 

is enough; 

however, there 

are some 

sources with 

high mineral, 

particulate, 

dissolved 

solids, and/or 

bacterial content 

that will 

require additional 

treatments.

Use Safety 

Indicator Strips 

whenever a 

weather event 

occurs (rain, 

etc.) that 

may change 

the water 

source’s 

composition.

Do not 

test tap 

water not 

treated with 

the MIOX 

Purifier because 

its chlorine 

content is 

not strong 

enough to 

register on 

strips. Strips 

measure free 

chlorine in 

the specific 

range produced 

by the 

 

MIOX Purifier

.

Replacements

Buy MIOX

®

 Purifier 

Replacement Test 

Strips/Salt with 

replacement Rock 

Salt and 

Safety Indicator 

Strips 

at any 

local or 

online MSR 

dealer.

Water 

Collection

Use the 

cleanest water 

available.

Use a 

bandana or 

MugMate™ Coffee/T

ea filter 

to remove 

solid par

ticles.

Use a 

Packtowl

®

 or 

sponge to 

collect water 

in ver

y small 

streams.

To 

improve the 

taste of 

water collected 

from less 

clean sources 

use vitamin 

C (ascorbic 

acid) or 

drink 

mixes after 

waiting the 

full treatment 

time.

Operation

The Purifier 

Cell holds 

a ver

y small 

amount of 

water (less 

than 1/4 

teaspoon).

Cold water 

does not 

affect treatment 

times.

In freezing 

temperatures the 

Salt Solution 

may freeze 

on the 

Salt Chamber 

screen and 

need to 

be 

rubbed or 

scratched clean 

with a 

fingernail.

Water 

containing ice 

may not 

be effectively 

treated by 

MIOX or 

other disinfectants. 

 

Ice can 

protect microorganisms.

Purifier

 

Storage Temperature 

Range -20-160 

F / 

-28-70 C 

 

Remove batteries 

with dr

y hands 

in a 

dry 

environment before 

long-term 

storage.

 

Rinse and 

dry 

inside of 

Purifier Cell 

and Salt 

Chamber before 

 

 

long-term 

storage. 

 

Store in 

cool, dr

y place.

Batteries

 

Storage Life 

7-10 years

 

Remove from 

purifier with 

dry 

hands in 

a dr

y  

 

environment before 

long-term 

storage.

 

Store in 

a cool, 

dry 

place.

Salt

 

Store sealed 

in bag 

to protect 

from moisture.

 

Store in 

a cool 

dry 

place.

Safety Indicator 

Strips

 

Storage Life 

2 years 

 

Store sealed 

in container 

to  

 

protect from 

moisture.

 

Store at 

room temperature.

159428-2

Drinkable Water

NaCL

H2O

I N S T R U C T I O N  

M A N U A L

MIOX

®

 PURIFIER

LIMITED LIFETIME WARRANTY/LIMITATIONS OF REMEDIES AND LIABILITY

USA and Canada

Limited  Warranty.  Cascade  Designs,  Inc.  (“Cascade”),  to  the  original  owner  (“Owner”),  under 

intended use and maintenance, warrants the enclosed product (“Product”) to be free from defects 

in materials and workmanship for the life of the Product.

 No warranty against defects in materials and 

workmanship will apply if Product is (i) altered in any way, (ii) used for purposes inconsistent with Product’s intended 

purpose or design, or (iii) improperly maintained. Warranty will furthermore be voided where user (i) failed to follow 

Product instructions or warnings or (ii) subjected Product to misuse, abuse, or neglect.

During the warranty period, original Product parts determined by Cascade to be defective in materials or workmanship 

will be repaired or replaced as Owner’s sole remedy. Cascade reserves the right to replace any discontinued product 

with a new product of comparable value and function. A returned product deemed irreparable becomes the property 

of Cascade and will not be returned.

EXCLUDING  THE  LIMITED  WARRANTY  PROVIDED  ABOVE,  CASCADE,  ITS  AFFILIATES  AND  THEIR  SUPPLIERS,  TO  THE 

MAXIMUM  EXTENT  PERMITTED  BY  LAW,  MAKE  NO  WARRANTIES,  EXPRESSED  OR  IMPLIED,  AND  DISCLAIM  ALL 

WARRANTIES, DUTIES AND CONDITIONS, WHETHER EXPRESSED, IMPLIED, OR STATUTORY, WITH RESPECT TO THE 

PRODUCT, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY, AGAINST LATENT 

DEFECTS, FITNESS FOR A PARTICULAR PURPOSE, OR CORRESPONDENCE TO DESCRIPTION.

Warranty  Service.

  To  obtain  service  under  this  warranty,  the  warranty-eligible  Product  must  be  presented  to  a 

Cascade  authorized  dealer.  In  the  United  States  and  Canada,  warranty  service  may  also  be  obtained  by  calling 

1.800.531.9531  [M-F,  8:00-4:30,  PDT].  Owner  is  responsible  for  all  costs  associated  with  returning  Product  to 

Cascade for service. Where at its sole discretion Cascade deems Product eligible for warranty repair or replacement, 

Cascade  will  pay  the  shipping  and  handling  associated  with  returning  repaired  or  replaced  Product  to  Owner.  In 

instances where Cascade deems a returned product ineligible for warranty service, Cascade will, if possible, repair 

product for a reasonable charge that includes return shipping and handling. For warranty return service details, please 

go to www.msrgear.com.

Limitation  of  Remedies.

  Should  a  court  of  competent  jurisdiction  find  the  limited  warranty  set  forth  above  breached, 

Cascade’s only obligation will be to, at its option, either repair or replace Product. Should the aforementioned remedy 

fail of its essential purpose, Cascade will, in exchange for return of Product, refund to Owner Product’s original purchase 

price. THE FOREGOING REMEDY IS THE SOLE AND EXCLUSIVE REMEDY OF THE PURCHASER AGAINST CASCADE, ITS 

AFFILIATES AND THEIR SUPPLIERS, REGARDLESS OF LEGAL THEORY.

Limitation of Liability.

 Cascade’s, its affiliates’ and their suppliers’ maximum liability is limited to incidental damages not 

to exceed the original purchase price of the Product. CASCADE, ITS AFFILIATES AND THEIR SUPPLIERS HEREBY DISCLAIM 

AND  EXCLUDE  ANY  LIABILITY  FOR  ANY  CONSEQUENTIAL  OR  OTHER  DAMAGES  RESULTING  FROM  ANY  REASON 

WHATSOEVER. THIS EXCLUSION AND LIMITATION APPLIES TO ALL LEGAL THEORIES UNDER WHICH DAMAGES MAY 

BE SOUGHT, AND WILL APPLY EVEN IF ANY REMEDY FAILS OF ITS ESSENTIAL PURPOSE.

This limited warranty gives Owner specific legal rights; Owner may have additional rights, which vary state to state.

Always completely follow safety, use, operation, and maintenance instructions for this or any other Cascade product.

European Union customer statutory rights are not affected.

For product ser vice and information contact

C a s c a d e   D e s i g n s ,   I n c .

®

4 0 0 0   F i r s t   Av e n u e   S o u t h ,   S e a t t l e ,   WA   9 8 1 3 4   U S A

P h o n e :   8 0 0 . 5 3 1 . 9 5 3 1   o r   2 0 6 . 5 0 5 . 9 5 0 0

w w w. m s r g e a r. c o m

See inside for detailed instructions.

TR

OU

BLE

SH

OO

TIN

G

SP

EC

IFI

CA

TIO

NS

TIP

S

STO

RA

GE

HOW THE MIOX

®

 PURIFIER WORKS

LED Activity

Problem

Meaning

Cause

Solution

SALT 

steady red 

 

(Low Salt)

Salt Solution 

 

too weak

Salt dr

y

Wet 

salt (see 

Step 1

)

Salt Solution 

trapped  

in Salt 

Chamber

Unscrew Top 

Cap, use 

thumb  

to hold 

salt & 

pour Salt 

Solution  

from Salt 

Chamber into 

Purifier Cell

Not enough 

salt in 

 

Salt Chamber

Add salt 

(see 

Step 1

)

Not enough 

water in 

 

Purifier Cell

Add water 

(see 

Step 1

)

Salt clogged 

in  

Salt Chamber 

screen

Use finger

nail to 

scrape  

screen clean

*Not enough 

salt in 

solution

Shake purifier 

again, 30-50 

times

Batteries cold

War

m batteries 

with body 

heat

BATT 

blinking red 

 

& RUN 

steady green

Battery 

charge  

low

Batteries 2/3 

depleted

MIOX

®

 Solution 

is safe 

to use. 

 

To 

prolong batter

y life 

use lower 

treatment clicks 

(1L clicks 

4X 

instead of 

4L clicks 

1X)

Batteries strained

Wait 

5+ minutes 

between  

activations

Batteries cold

War

m batteries 

with body 

heat

BATT 

steady red

Battery 

charge  

too low 

for  

activation

Replace batteries

No Lights

Battery 

 

connection faulty

Check Batter

y Contact 

Strip  

(See 

Step 2

)

Batteries dented

Replace batteries

Batteries dead

Replace batteries

Safety Indicator 

Strips

Problem

Solution

Strips unavailable, 

expired, 

or not 

turning 

purple

Add 8 

treatments to 

the water 

and wait 

the appropriate 

time 

(Ex. 4L 

clicks 2X 

added to 

1L water)

*Water 

sources with 

very 

high levels 

of tannins 

or calcium 

carbonate may 

bind with 

the salt. 

In rare 

cases, a 

small vial 

of tap 

water may 

need to 

be brought 

and used 

to make 

the treatment 

solution. The 

last few 

drops of 

water left 

in the 

container may 

also be 

used.