These settings are queried in sequence:
●
Baud rate configurable to 38400, 57600, or 115200, depending on the value configured
for the interface on the computer only when connecting via serial port.
●
XP and YP in the second and third menu point, you can calibrate the stencil cutter
correctly. Correction may be required here due to wear to the mechanical parts. The X
and Y scaling of the data can be changed by changing the XP and YP values. If, for
example, an object for which a length of 100 cm was entered on the computer is cut on
the stencil cutter to a length of only 98cm, it is necessary to correct the corresponding
scaling value on the plotter. Otherwise, these values should not be changed.
●
Reset settings here you can restore the stencil cutter's factory settings. To do so, the
right arrow key must be held for 3 seconds.
●
Firmware here you can view the firmware version installed on the cutter.
.
Calibration:
Before the first use, the cutter requires an initial calibration to determine the correct blade offset.
DrawCut provides two procedures to achieve this, one fast and one detailed option.
●
The first step is to open the "Vinyl Spooler".