3-10 Fast Installation
Rev AE
MSSC QM1610 Operator Manual
Note:
Install tie-wrap to act as strain relief for the wire.
5
Refer to Figure 3-12 while performing the wiring. Also, refer to the
sensor description provided in Table 3-1.
The wiring description for the sensor (PN: 35464) is as listed in the
following table:
6
Replace the cover of the externally-connected sensor and fasten the
bolt.
7
Fix the sensor onto the production line. Make sure that the distance
from the sensor to the nozzle is not greater than 500 mm.
Note:
You must set the printer software properly while using the external
photocell. With an external photocell,
Auto Detect
is not used to set speed or
direction. Use the 'Set Line' option in the main menu (
Set Production Line
on page 4-21) to manually set the speed, the direction and to set the 'Select
Sensor' setting to 'External'.
8
Power supply installation:
Warning
PERSONAL INJURY. Make sure that the mains socket outlet is
installed in the vicinity of the equipment so that it is easily
accessible.
Sensor
Wire
Color
Controller Wiring
Base
Remarks
Red
12 V
Short connected 12 V and SIG+ by using
wire
White
SIG -
Black
GND
Table 3-1: Wiring Description
Figure 3-12: Wiring Details