background image

AutoFry 

OFS Operator’s Manual

 

 

11 

OFS OM REV 02/19 

63-0108 

Filtering Oil in the AutoFry:

 

 

**FILTER OIL BELOW 300°F BUT ABOVE 200°F 

 

 

**BE SURE TO ALWAYS WEAR PROTECTIVE GEAR** 

1.

 

Make sure the OFS Vat is clean and empty to avoid overflow. 

 
 
 

BE SURE THE AUTOFRY IS TURNED OFF UNTIL IT IS FILLED WITH OIL! 

 

2.

 

Ensure the splash guards are inserted into the cutouts in the vat cover to avoid     
leaking.  
 

3.

 

Slowly open the drain valves and let the oil completely drain into the OFS Vat. 
 

4.

 

Close the drain valves.  

 

5.

 

Turn the main valve to 

“Left Vat” or “Right Vat” (whichever you want filled first).

 

 

6.

 

Flip the ON / OFF switch to the left of the valve to the ON position to begin pumping. 

 

7.

 

When the upper (hot) fill line is reached, flip the ON / OFF switch to the OFF position. 

 

8.

 

Turn the valve to the opposite side vat. 

 

9.

 

Flip the ON / OFF switch to the ON position to begin pumping. 

 

10.

 

When the upper (hot) fill line is reached, flip the ON / OFF switch to the off position. 

 

11.

 

Return the valve to the “OFF” position.

  

 
 
 
 
 
 
 

Summary of Contents for AUTOFRY OFS

Page 1: ...E167654 AUTOFRY OFS Oil Filtration System Operator s Manual ...

Page 2: ...E167654 AUTOFRY A Patented Product of Motion Technology Inc 10 Forbes Road Northborough MA 01532 Tel 800 348 2976 508 460 9800 Fax 508 393 5750 ...

Page 3: ...8 PREPARING THE OFS 9 FILLING WITH FRESH OIL 10 FILTERING OIL 11 DISPOSAL OF OLD OIL 12 CLEANING MAINTENANCE 13 WASTE DISPOSAL 13 TROUBLESHOOTING GUIDE 14 TABLE OF FIGURES FIGURE 1 OFS BREAKDOWN 5 FIGURE 2 QUICK DISCONNECTS 5 FIGURE 3 CARBON PAD FILTER INSTALLATION 6 FIGURE 4 VALVE ACCESS PANEL 7 FIGURE 5 VALVE DECAL 7 FIGURE 6 DRAIN VALVES 7 FIGURE 7 HOSE CONNECTIONS 8 FIGURE 8 DISCHARGE WAND ASS...

Page 4: ...ations ordinary wear and tear resulting from use failure to change filters using only manufacturers supplied at the recommended intervals or if the installation does not comply with set up and installation instructions or any other circumstance beyond the control of MTI The equipment shall not have been previously altered repaired or serviced by anyone other than a service facility authorized by M...

Page 5: ...Symbols Caution Important Risk of Electric Shock Danger of Slipping Danger of Burning Risk of Fire Caution Hot Operation Instruction Designated Use The OFS is designed for use in the AutoFry MTI 40E in commercial kitchens Follow safety instructions Filtration is only possible if the oil is liquid The OFS should only be used by suitably trained staff Non Designated Use The nonobservance of the cont...

Page 6: ...to filtering or draining the oil vat s There is a risk of fire due to a low or no oil condition NEVER operate the filtration system without oil NEVER use the filtration system to pump water Water will damage the pump assembly enough to require a replacement IMPORTANT Ensure the OFS Vat is empty prior to draining the oil to avoid potential overflow Closely monitor your progress oil level when filte...

Page 7: ...ck on the white round female quick disconnect Figure 2 When reconnecting pull back on the female quick disconnect and be sure the male end is firmly seated before releasing The two should lock together 2 Turn the vat cover lock and lift to remove the vat cover You will need to maneuver the stem through the vat cover clearance hole 3 Lift the stem and filter foot out of the OFS vat Quick Disconnect...

Page 8: ...e 3 2 Install a new carbon pad by aligning the notch of the filter with notch on the filter foot 3 Close the release handle 4 Reverse the steps on page 5 to reinstall the filter foot and stem back into the OFS vat The Carbon pad filter should be replaced after each filtration or as needed To reorder carbon pad filters Call 1 800 348 2976 x 154 Or order online at www autofrywebstore com P N 48 0035...

Page 9: ...es whether oil is replenished to the left or right AutoFry oil vat THIS VALVE MUST BE RETURNED TO OFF AFTER REPLENISHING OIL Figure 5 Open the lower AutoFry doors to access the drain valves Figure 6 Drain Valves These valves are used to drain the oil from the AutoFry oil vats Turn valve handle down to open Figure 6 shows the drain valves in the closed position THESE VALVES MUST REMAIN CLOSED ANYTI...

Page 10: ...foot stem to the pump inlet fitting Disconnect this hose from the stem when changing the carbon pad filter Discharge Wand Assembly Connects to the pump discharge fitting when disposing of old oil Can also be used to manually pump oil into the AutoFry through the front door This allows you to pump oil throughout the AutoFry vat to flush out built up sediment in the AutoFry vat Should be stored in a...

Page 11: ...l be a risk of overflow 4 Ensure the hose from the filter foot to the pump inlet is firmly connected on both ends 5 Ensure the hose from the AutoFry to the pump discharge is firmly connected 6 Ensure that the power cord from the OFS to the machine outlet is firmly seated on both ends and the pump on off switch is in the ON position 7 Ensure that the ON OFF Switch behind the valve access door is in...

Page 12: ...both drain valves are closed 4 Turn the main valve to Left Vat or Right Vat whichever you want filled first 5 Flip the ON OFF switch to the left of the valve to the ON position to begin pumping 6 When the lower cold fill line is reached flip the ON OFF switch to the OFF position 7 Turn the valve to the opposite side vat 8 Flip the ON OFF switch to the ON position to begin pumping 9 When the lower ...

Page 13: ...Slowly open the drain valves and let the oil completely drain into the OFS Vat 4 Close the drain valves 5 Turn the main valve to Left Vat or Right Vat whichever you want filled first 6 Flip the ON OFF switch to the left of the valve to the ON position to begin pumping 7 When the upper hot fill line is reached flip the ON OFF switch to the OFF position 8 Turn the valve to the opposite side vat 9 Fl...

Page 14: ...oFry 7 Disconnect the hose to the pump discharge fitting This hose will remain attached to the AutoFry 8 Completely remove the OFS and turn the pump ON OFF switch to the OFF position 9 If the disposal requires transportation to a remote location use extreme caution to avoid spilling 10 Firmly connect the discharge wand to the pump discharge fitting 11 With the pump switch in the OFF position plug ...

Page 15: ... soapy water followed by a clear water rinse Thoroughly dry all parts Install a new carbon pad filter See page 5 Reassemble and install OFS underneath AutoFry Waste Disposal Packaging Disposal The packaging should either be recycled or kept carefully Filter Disposal Used filters must be disposed of in the country specific way Device Disposal If the OFS reaches its end of life it must be disposed o...

Page 16: ...AutoFry OFS Operator s Manual 14 OFS OM REV 02 19 63 0108 ...