background image

GENERAL INSTALLATION GUIDELINES

•  Set tub into final location and use a level on the top of the tub to    

 

 

 ensure ALL SIX leveling feet are in contact with the floor. The unit  

 

  

 

must be level for proper operation and to ensure door seal will not  

 

  

 

leak. Do not remove the leveling feet! No additional support or    

 

 

bedding is required. If your tub was ordered with a factory installed  

 

 

tile flange, attach tile flange to studs, fill in void at edge of tub with  

 

 

clear silicone.

 (See diagram to the right)

•  Secure tub frame to studs using metal straps (not provided).

•  Complete drain installation and test. This tub comes with a cable style drain that attaches to the small door   

 

drain. Important Note! There is 3/8” flexible tubing pre-installed to the door drain. This tubing MUST be  

 

 

connected to the small output on the drain shoe. Failure to make this critical connection will result in leaking  

 

not covered under warranty. Completely install the drain assembly and check for leaks prior to the final  

 

 

installation. MTI Baths is not responsible for leaks associated with improper installation or testing of drain.

Additional installation information for walk-in tubs equipped with 

optional valve package

Package includes hot & cold valves, hand shower, diverter and backflow 

prevention device which are factory-installed. The unit is also equipped with 

a Virtual Spout located on the side wall of the tub. This takes the place of a 

traditional filler spout.
Simply connect your incoming hot and cold water lines to the corresponding 

hot and cold rough in valves. The tub will fill through the Virtual Spout port 

located on the inside wall of tub.

•   Check all fixtures for proper operation and leaks.

•   Plug in the pump or blower. Fill tub to normal level and test for leaks and operation.

Installation Instructions for Optional Extension Kit

•  Complete installation of tub and water test according to directions. 

•  Build a simple stud wall to fill the gap between the tub and the existing structure.

•  The wall will need to be measured very carefully. If your wall is too wide or deep,the extension panels will    

 

not install flush with the tub. The height of the wall should be the height of your finished tub, less the  

 

 

thickness of the top extension piece (approx. 1 ¾”). The depth of the wall should be the depth of the tub,    

 

less the thickness of the front removable panel. Please measure all materials on site to ensure a perfect fit. 

•  Once wall is built to the correct specifications, the top and front panels can be adhered to the framing  

 

 

using construction adhesive. If desired, run a small bead of clear silicone between the extension kit and tub. 

Installation Instructions for Radiance

®

Each Radiance

® 

system comes with an on/off touch pad and transformer box equipped with a 27” power cord. 

There are two heated zones for each Radiance system purchased. To install, simply plug the transformer box 

into a 110V, GFCI protected outlet. The transformer box draws 5 amps.

Virtual Spout 

4

Summary of Contents for BASICS Series

Page 1: ...the product owner Please note important information below Distributor Name Model Manufacturer s Date Serial O W N E R S M A N U A L I N S TA L L AT I O N G U I D E E f f e c t i v e J a n u a r y 1 2...

Page 2: ...or purchasing an MTI Baths BASICS series Walk in Tub You have chosen a high quality bath hand crafted with pride in the USA The instructions in this booklet will provide you with the information you n...

Page 3: ...e the hydrotherapy bath while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers Persons with a medical history...

Page 4: ...THE TUB S CONDITION IT IS THE RESPONSIBILITY OF THE INSTALLER TO THOROUGHLY TEST THE UNIT PRIOR TO INSTALLATION TUBS ARE INTENDED AND WARRANTIED FOR INDOOR USE ONLY TEST PROCEDURES 1 Place the tub on...

Page 5: ...t flowing indicating the possibility of electric shock Do not use this unit Disconnect the unit and have the problem corrected by a qualified electrician before using 2 Each whirlpool pump air blower...

Page 6: ...of the tub This takes the place of a traditional filler spout Simply connect your incoming hot and cold water lines to the corresponding hot and cold rough in valves The tub will fill through the Virt...

Page 7: ...ystem After using the tub briefly turn the system on then turn off You do not need to fill the bath before doing this This will activate the 20 minute delayed purge cycle and keep the system clean and...

Page 8: ...These may have loosened during shipment or installation These need to be hand tight only 2 Remove both unions and check the rubber O rings for proper seating Replace unions hand tight LITTLE OR NO AC...

Page 9: ...damp cloth 5 Clean grease oil paint or ink stains with isopropyl rubbing alcohol Dry with a clean soft cloth 6 Avoid using razor blades or other sharp objects that might scratch the surface Small scra...

Page 10: ...aordinary acts such as earthquakes hurricanes lightning floods hail etc MTI Baths is NOT liable for incidental or consequential damage loss of time inconvenience incidental expenses labor or material...

Page 11: ...oper maintenance incorrect or inadequate water use use of improper cleaners or extraordinary acts such as earthquakes hurricanes lightning floods hail etc MTI Baths is NOT liable for incidental or con...

Page 12: ...Manufactured by MTI Baths Inc mtibaths com 670 N Price Road Sugar Hill GA 30518 800 783 8827 770 271 8228 Fax 800 438 8827 Copyright 2014 by MTI Baths Inc Modification Rights Reserved 0114...