background image

Installation and Operational Manual

 • 

Boutique Collection

 • 

 SculptureStone® Tubs

1 / mtibaths.com

Do not permit children to use this unit unless they are closely supervised by an adult at all times. Supervision is also required when bath 

is used by an elderly or handicapped individual.
Never leave a full or filling bath unattended.
Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer. Never 

drop or insert any object into any opening.
The water in a bath should never exceed 40˚ C (104˚ F). Water temperatures between 38˚ C (100˚ F) and 40˚ C (104˚ F) are considered safe 

for a healthy adult. Use time should be limited to approximately 10 minutes, followed by a shower to cool down. Longer exposures may 

result in hyperthermia, which can be fatal. The symptoms of this condition are nausea, dizziness and fainting. Lower water temperatures 

are recommended for extended use (exceeding 10 - 15 minutes) and for young children.
Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, pregnant or 

possibly pregnant women should limit water temperatures to 38˚ C (100˚ F).
The use of drugs or alcoholic beverages before or during bathing may lead to unconsciousness with the possibility of drowning. Never 

use the bath while under the influence of alcohol, anticoagulants, stimulants, antihistamines, vasoconstrictors, vasodilators, hypnotics, 

narcotics or tranquilizers.
Persons using medication should consult a physician before using a bath since medication may induce drowsiness while other 

medications may affect heart rate, blood pressure and circulation.

DANGER:

 

To reduce the risk of injury, enter and exit the bath slowly.

Never operate electrically connected devices in or within 5' of the bath. Never drop or insert any object into any opening within the bath.

Risk of electric shock. Connect only to circuits protected by a Ground Fault Circuit Interrupter (GFCI). Such a device should be installed by 

a licensed electrician and should be tested on a regular basis (at least monthly). To test the GFCI push the TEST button. The GFCl should 

interrupt the power. Push the RESET button and the power should be restored. If the GFCI fails to operate in this manner there is the 

possibility of an electric shock. DO NOT USE. Disconnect the unit and have the problem corrected by a qualified service technician. To 

avoid the possibility of personal injury and discoloration of the acrylic surface, the inlet water temperature should not exceed 60˚ C (140˚ F).

Disconnect power before servicing.

A pressure wire connector is provided on the exterior of the pump or control within this unit to permit connection of a bonding conductor 

between this unit and all other exposed metal in the vicinity, as needed to comply with local requirements.

INSTALLER/OWNER BEARS ALL RESPONSIBILITY TO COMPLY WITH ALL 

STATE AND LOCAL CODES WHEN INSTALLING THIS PRODUCT.

IMPORTANT:

 When required by local codes, install a RPZ (Reduced Pressure Zone) backflow prevention device to each faucet supply 

line.

Important Safety Instructions

This manual contains information and instructions for proper operation and maintenance of your MTI bathtub. Failure to follow these 

instructions could result in personal injury, electrical shock or fire.

WARNING: WHEN USING ELECTRICAL PRODUCTS, BASIC PRECUATIONS SHOULD BE 

FOLLOWED INCLUDING THE FOLLOWING:

SAVE THESE INSTRUCTIONS

Summary of Contents for Boutique SculptureStone 131

Page 1: ...ne Tubs Installer This booklet must be given to the product owner Please note important information below Distributor Name _______________________________________ Model _______________________________...

Page 2: ...This information is also available on mtibaths com Our customer service department is available to answer any additional questions you may have pertaining to the installation of your bath Please call...

Page 3: ...n Dimensions 3 Freestanding Tubs 4 5 Drain Installation 4 Freestanding Tubs with Cradle 5 Alcove Tubs 6 Air Baths 7 9 Electrical Specifications 7 Hydrotherapy Operating Instructions 10 Care and Cleani...

Page 4: ...fect heart rate blood pressure and circulation DANGER To reduce the risk of injury enter and exit the bath slowly Never operate electrically connected devices in or within 5 of the bath Never drop or...

Page 5: ...o factory before tub is installed Defects or damage claimed after installation will be excluded from warranty Ensure location is structurally sound flat and level See individual specification sheets f...

Page 6: ...4 247 8 1 4 248 8 249 8 253 25 260 10 262 8 The toe tap drain kit for these tub models includes a straight PVC fitting for weld adhesive connection to the drain pipe directly underneath the tub drain...

Page 7: ...will vary slightly from tub to tub box out around the pipe to allow trimming this pipe below grade upon installing the MTI supplied fitting The fitting is approximately 3 in diameter 2 Determine gap b...

Page 8: ...into cradle 5 Install toe tap drain on tub using clear silicone under the waste flange and on both sides of the silicone gasket on underside of the tub Tighten brass hold down nut until it seats plus...

Page 9: ...rim Installation Instructions Alcove Tubs Determine the final height of your stringers by measuring the tub from the underside of the rim to the floor Mark a level line on the stud walls using the mea...

Page 10: ...he air system The GFCI outlet must be accessible for future servicing Note MTI does not recommend locating the blower more than 8 from the tub to prevent heat loss from the blower to the tub 1 schedul...

Page 11: ...nsor Remote Control Keypad Installation The water sensor wire factory installed to posts under the tub on either side of the tub drain Photo B will connect to a port on the side of the blower See Illu...

Page 12: ...Wires Wires lead from sensors mounted on either side of tub drain and connect to blower Allows activation of purge cycle after tub has drained Remote Control Receiver Connection to blower required for...

Page 13: ...cycle countdown This countdown cannot be cancelled Any attempt to cancel this cycle only resets the countdown timer Press hold to decrease the blower speed Release pressure at the desired speed 2nd P...

Page 14: ...inish Also avoid any cleaners that include lime removal agents such as CLR or Lime A Way as these can also damage the finish 7 Avoid any bath products that contain natural or artificial dyes Test prod...

Page 15: ...uire the services of a professional repair technician To verify turn the air system on high for 4 5 minutes you do not need to have water in the tub Carefully feel the grey air hose where it exits the...

Page 16: ...rms of this warranty No payment for services rendered will be made by MTI Baths without an MTI authorized service order To obtain service for any malfunction or defect contact MTI s Technical Service...

Page 17: ...ccess must be provided to each air blower and or electrical component on your tub The access panel s must have a minimum size of 16 x14 for installation and future servicing of the equipment MTI Baths...

Page 18: ...obtain service for any malfunction or defect contact MTI s Technical Service Warranty Department in writing within 10 days of the discovery of the problem Proof of purchase must be provided Other supp...

Page 19: ...requested In the event that the carrier fails to respond report such response to both the seller and the carrier Any freight claims must be filed within ten business days The check valve on all air b...

Page 20: ...Installation and Operational Manual Boutique Collection SculptureStone Tubs 17 mtibaths com NOTES...

Page 21: ...Installation and Operational Manual Boutique Collection SculptureStone Tubs 18 mtibaths com NOTES...

Page 22: ...NOTES...

Page 23: ...MTI Baths 670 North Price Road Sugar Hill GA 30518 p 800 783 8827 f 800 438 8827 Made in the USA mtibaths com Copyright 2021 by MTI Baths Inc Modification Rights Reserved 0621...