background image

 SECURE PLUG

™ (PATENT PENDING) 

USER GUIDE

12

 MTI P/N 063-00243 rev B ©2018 MTI All Rights Reserved

www.mobiletechinc.com  |  T:800.426.6844

FCC AND ISED STATEMENT

This device complies with Innovation, Science and Economic Development Canada licence-exempt RSS standard(s). Operation is subject to the following 
two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause 
undesired operation of the device.

CAN ICES-3(B)/NMB-3(B)

Le présent appareil est conforme aux CNR Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. 
L’exploitation est autorisée aux deux conditions suivantes:

(1) il ne doit pas produire de brouillage et (2) l’ utilisateur du dispositif doit étre prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage 
est susceptible de compromettre le fomctionnement du dispositif.

CAN ICES-3(B)/NMB-3(B) 

The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS-102 RF exposure, users can obtain 
Canadian information on RF exposure and compliance. 

Le dispositif rencontre l’exemption des limites courantes d’évaluation dans la section 2.5 de RSS 102 et la conformité à l’exposition de RSS-102 rf, 
utilisateurs peut obtenir l’information canadienne sur l’exposition et la conformité de rf. 

This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated 
with a minimum distance of 20 millimeters between the radiator and your body. 

Cet émetteur ne doit pas être Co-placé ou ne fonctionnant en même temps qu’aucune autre antenne ou émetteur. Cet équipement devrait être installé et 
actionné avec une distance minimum de 20 millimètres entre le radiateur et votre corps.

MTI declares that the radio equipment models 165-00460, 165-00470 and 165-00471 Secure Plug Power distribution units including the 
models 165-00645 and 165-00670 Remote Access Modules in compliance with EU Directive 2014/53/EU.  

The full text of the EU Manufacturer’s Declaration of Conformity is available at the following internet address: www.mobiletechinc.com

This device complies with Part 15 of the FCC Rules.

Caution: If any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the 
equipment.

Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference 
received, including interference that may cause undesired operation.

The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could 
void the user’s authority to operate the equipment.

The RF Exposure Compliance distance is 20 millimeters.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These 
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can 
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more 
of the following measures:

—Reorient or relocate the receiving antenna.

—Increase the separation between the equipment and receiver.

—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

—Consult the dealer or an experienced radio/TV technician for help.

Technical Data
Model: 165-00471

Operating Frequency: 

125KHz

Operating Temperature: 

0° C to 40° C

Max Power: 

125KHz: <42dBuA/m at 10m

Technical Data
Model: 165-00645 / 165-00670

Operating Frequency: 

125KHz, 2.4GHz: 2405-2480MHz

Operating Temperature: 

0° C to 40° C

Max Power: 

125KHz: <42dBuA/m at 10m

 2.4GHz: 

<20dBm 

FCC ID: 2AA2X-165-ØØ471
Model: 165-00471
FCC Statement

FCC ID: 2AA2X-165-ØØ645-24
Model: 165-00645 / 165-00670
FCC Statement

ISED Certifcation Number: 24439-165ØØ471
Model: 165-00471
ISED Statement

ISED Certifcation Number: 24439-165ØØ64524
Model: 165-00645 / 165-00670
ISED Statement

Merchandising Technologies Inc.
Unit B, 9/F., Great Wall Factory Building 11 Cheung Shun Street,Lai Chi Kok,Kowloon, Hongkong

Summary of Contents for SECURE PLUG 165-00471

Page 1: ...E PLUG DO NOT REMOVE FROM STORE Contents 1 Materials in Box 2 2 Installation 3 3 Key Whitelist 4 4 Merchandising 5 5 Arming Disarming the System 7 6 Remerchandising 8 7 Adding New User Keys 8 8 Deleting Whitelist 8 9 LED Status Indicators 9 10 FCC and ISED Statement 12 For additional support please reach out to our Contact Center at 800 426 6844 CONTENTS ...

Page 2: ...NT PENDING USER GUIDE 2 MTI P N 063 00243 rev B 2018 MTI All Rights Reserved www mobiletechinc com T 800 426 6844 MATERIALS IN BOX Remote Access Module Optional Alarm Label Sheet Secure Plug Power Strip Region Specific ...

Page 3: ...screw heads exposed Align the Power Strip keyholes circled in blue and hang onto the screws WARNING No user serviceable parts inside Please contact MTI for service CAUTION To Reduce the Risk of Electric Shock Use Only Indoors CAUTION Risk of Electric Shock Do not plug into another relocatable power tap or an extension cord CAUTION Use Only in Dry Locations AVERTISSEMENT Aucune pièce réparable par ...

Page 4: ...list process can be done on the Secure Plug unit or through the Remote Access Module Place the User Key over the RFID icon you want to add If successful Æ unit beeps 2 times If unsuccessful Æ unit beeps 4 times retry Repeat process for all User Keys until they are successfully added To close the whitelist mode place the Authorization Card over the RFID icon Whitelist mode will end automatically af...

Page 5: ...ote Access Module will show a corresponding red LED for that socket port Unplug cable from the Power Strip and try again making sure cables are unplugged from the product Unplug any cables from the product end for products that have removable power cords If the product does not have a removable power cord turn the power to the product to OFF 9 8 NOTE Only supports products up to 10A SECURE PLUG PA...

Page 6: ...larm label to product end of cable if desired Turn the power to products with a detachable power adapter to ON at this time Keep power to other products OFF ie hardwired products or products without power adapters SECURE PLUG PATENT PENDING USER GUIDE 6 MTI P N 063 00243 rev B 2018 MTI All Rights Reserved www mobiletechinc com T 800 426 6844 MERCHANDISING ...

Page 7: ...e power to products to ON or OFF at this time as desired If any cable becomes unplugged the system will alarm LED will flash red white The Remote Access Module will show a corresponding red LED for that socket port To re arm fix the issue by plugging all cables back in Place a User Key over the RFID icon and the LED will be solid white Placing a User Key over the RFID icon will silence the alarm The...

Page 8: ...st process starting on page 4 Merchandise a new product by following the process on page 5 If you did not unplug a product there is no need to remerchandise the product again From an Alarming state place the User Key over the RFID icon to silence the alarm Then hold down the User Key for 5 seconds to return back to the disarmed state LED will be flashing white From an Armed state place the User Key...

Page 9: ...sarmed and needs to be re armed 2 System is calibrating product wait until successful or unsuccessful merchandising before proceeding LED is flashing red and white Alarm System is alarming and needs to be attended to LED is flashing red Mains Power Loss Mains power loss has occurred System will alarm for 5 minutes Whitelist and merchandising information will be maintained upon restoration of power L...

Page 10: ... has gone into overcurrent protection Unplug any product which may be drawing too much power LED is flashing blue Overcurrent Disarmed System has gone into overcurrent protection and user has disarmed the system Unplug any product which may be drawing too much power The system will self heal LED is flashing yellow 1 Ready to be Armed without MTI Connect Mesh Connected 2 Merchandising Calibration wit...

Page 11: ...cess again 2 System is alarming on corresponding socket port and needs to be attended to See main LED for overall system status LED is flashing blue 1 Provisioning Mode 2 Overcurrent Disarmed 1 System has entered Mesh network provisioning mode If it s within range of a Hub that is also in provisioning mode it will join the Hub s network within 5 seconds and it will stop flashing blue 2 System has go...

Page 12: ...device complies with Part 15 of the FCC Rules Caution If any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause...

Reviews: