background image

G. Finish Strip

Parallel to deck flutes

      (required for metal deck

B. Bottom Section

A. Top Section

H. Closure Strip

Perpendicular to deck flutes

       (required for metal deck)

C. End Cap Insert

Slides into exposed end of bottom section

Installation Guide for

 

EdgeBox RI

 

FM

Approved

ANSI/SPRI/FM4435/ES-1 TESTED

 FINISH STRIP

(TYPE 2 SHOWN)

CORRUGATED ROOF
DECK BY OTHERS

CONCEALED
JOINT SPLICE

FASTENER

 FASTENER
 6" F.E. / 12" O.C. (TYP. 4)

TOP SECTION

BOTTOM SECTION

OPTIONAL INSULATION
BY OTHERS

MEMBRANE BY OTHERS

ROOF SIDE

A

B

H

OPTIONAL

INSULATION

(BY OTHERS)

ROOF DECK

(BY OTHERS)

G

C

E

12" OC

D

F

D. Fastener

Included and required

F. EdgeBox Spine

Required for height or width greater than 6"

CLOSURE STRIP

FASTENER
PROVIDED

E. Fastener

       Size varies based on height of EdgeBox
       min. 1" penetration required

NOTES:
#1  -  Isolate  all  metal  parts  from  ACQ  treated  wood  or  other  galvanically
incompatible material with appropriate membrane material.
#2  -  Appliance  attachments,  such  as  lightning  rods,  signs,  or  antennae

that  penetrate  the  edge  system,  induce  a  galvanic  reaction,  or  otherwise
compromise the effectiveness of the roof edge system, shall be eliminated
or isolated to prevent problems per 

ANSI/SPRI/FM4435/ES-1

.  

Lightning

protection systems for example must not be directly affixed to the product
provided  by  Hickman.  Consult  Hickman  for  alternative  attachment
suggestions.