13.5 ATEX/IECEx
13.5.1 ATEX/IECEx IS
13.5.1.1 Specific conditions of safe use
1. When EPL Ga or Da is required, parts of the equipment containing
light metals (Aluminum or Titanium) shall be protected from
impact so that impact or friction sparks cannot occur, taking into
account rare malfunction. Measures to prevent impact or friction
sparks when using the equipment containing light metals include
but are not limited to:
• Mounting the probe vertically
• No mechanical agitation shall be used
• Use of stilling wells to mitigate effect of agitation.
• Limit rate of change of level to values such that friction sparks
cannot occur
2. The maximum permitted ambient temperature of the Level Plus
Digital/Analog Level Transmitter is 71 °C. To avoid the effects of
process temperature and other thermal effects care shall be taken
to ensure the surrounding ambient and the ambient inside the
transmitter housing does not exceed 71°C
3. Warning: The equipment contains non-metallic enclosure and
process parts. To prevent the risk of electrostatic sparking, the
non-metallic surface should only be cleaned with a damp cloth.
Painted surface of the equipment may store electrostatic charge
and become a source of ignition in applications with a low relative
humidity <~30% relative humidity where the painted surface is
relatively free of surface contamination such as dirt, dust or oil.
Cleaning of the painted surface should only be done with a damp
cloth.
4. The applicable temperature class, process temperature range and
ambient temperature range of the equipment is as follows;
• T3 with Process Temperature Range of -40°C to 150°C
• T4 with Process Temperature Range of -40°C to 135°C
• T5 with Process Temperature Range of -40°C to 100°C
• T6 with Process Temperature Range of -40°C to 85°C
• Ambient Temperature Range -40°C < Ta < 71°C
1
1
2
A
A
B
B
REV
ECO #
DESCRIPTION
TITLE
SIZE DWG NO.
REV
PRODUCT LINE
SCALE:
BY
DATE
SHEET
OF
UNLESS OTHERWISE SPECIFIED
TOLERANCES
0 PLACES
MM
1 PLACE
MM
ANGLES
0.5
0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS
- DRILL DEPTHS ARE TO FULL DIA.
- REMOVE BURRS AND SHARP EDGES
- DO NOT SCALE PRINT
- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATA
THE INFORMATION AND DESIGN(S) DISCLOSED
HEREIN ARE THE PROPERTY OF MTS SYSTEMS
CORPORATION AND MAY NOT BE USED,
REPRODUCED OR DISCLOSED IN ANY FORM
EXCEPT AS GRANTED IN WRITING BY MTS
SYSTEMS CORPORATION. THIS RESTRICTION
EXCLUDES INFORMATION THAT IS IN THE
PUBLIC DOMAIN OR WAS LEGITIMATELY IN THE
PRIOR POSSESSION OF THE RECIPIENT.
m
MTS SYSTEMS CORPORATION
SENSORS DIVISION
3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST
ANGLE
551629-3
C
1
1
DRAWN BY: NJ
A
NJ
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
WARNING: REFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGS
FM14ATEX0068X
IECEx FMG 14.0032X
II 1/2 G Ex ia IIC T4 Ga/Gb
Ta = -50°C to +71°C ; IP65
when connected in accordance
with FM approved installation
drawing # 651543-3
MTS Systems Corporation
Sensors Division
3001 Sheldon Dr.
Cary, NC 27513
Model No:
Serial No:
Date :
R
ENTITY PARAMETERS:
SEE PRINT REFERENCE CHART
LEVEL
1:1
7570
RELEASE TO PRODUCTION
(ACP) LABEL, LP, IS ATEX/IECEx - DIGITAL
10/24/14
2809
Level Plus
Transmitter
P/N 551629-3 Rev C
NOTES:
STANDARD LETTERING UNIVERS 55
OR ITC GARAMOND BOOK.
DIMENSIONS IN BRACKETS [ ] ARE
IN INCHES.
3. MATERIAL: 3M 7883 METALLIZED
POLYESTER FOIL W/GAS RESISTANT
INK.
IP RATING WAS 66
1/19/15
NJ
7847
B
C
8176
CHANGED CE TO 2809
MS
5-21-19
Fig. 54: Intrinsically Safe FMC label, Modbus and DDA, NEMA Housing
Fig. 55: Intrinsically Safe ATEX/IECEx label, Modbus and DDA, NEMA Housing
1
1
2
A
A
B
B
REV
ECO #
DESCRIPTION
TITLE
SIZE DWG NO.
REV
PRODUCT LINE
SCALE:
BY
DATE
SHEET
OF
UNLESS OTHERWISE SPECIFIED
TOLERANCES
0 PLACES
MM
1 PLACE
MM
ANGLES
0.5
0.1
- THREAD DEPTHS ARE TO MIN. FULL THDS
- DRILL DEPTHS ARE TO FULL DIA.
- REMOVE BURRS AND SHARP EDGES
- DO NOT SCALE PRINT
- MACHINED SURFACE FINISH 3.2uM [125 uIn]
PROPRIETARY DATA
THE INFORMATION AND DESIGN(S) DISCLOSED
HEREIN ARE THE PROPERTY OF MTS SYSTEMS
CORPORATION AND MAY NOT BE USED,
REPRODUCED OR DISCLOSED IN ANY FORM
EXCEPT AS GRANTED IN WRITING BY MTS
SYSTEMS CORPORATION. THIS RESTRICTION
EXCLUDES INFORMATION THAT IS IN THE
PUBLIC DOMAIN OR WAS LEGITIMATELY IN THE
PRIOR POSSESSION OF THE RECIPIENT.
m
MTS SYSTEMS CORPORATION
SENSORS DIVISION
3001 SHELDON DRIVE, CARY, NC 27513
METRIC
FIRST
ANGLE
551641-3
C
1
1
DRAWN BY: MS
***NO REVISIONS SHALL BE MADE WITHOUT THE NOTIFICATION TO APPROVAL AGENCY(S).***
WARNING: REFER TO INSTALLATION DRAWING FOR CAUTION/WARNINGS
FM14ATEX0068X
IECEx FMG 14.0032X
II 1/2 G Ex ia IIC T4 Ga/Gb
Ta = -50°C to +71°C ; IP65
when connected in accordance
with FM approved installation
drawing #
651544-3
Model No:
Serial No:
Date:
MTS Systems Corporation
Sensors Division
3001 Sheldon Dr.
Cary, NC 27513
LEVEL
1:1
(ACP) LABEL, LP, IS ATEX/IECEx - ANALOG
Level Plus
Transmitter
2809
P/N 551641-3 Rev C
NOTES:
1. STANDARD LETTERING UNIVERS 55
OR ITC GARAMOND BOOK.
2. DIMENSIONS IN BRACKETS [ ] ARE
IN INCHES.
3. MATERIAL: 3M 7883 METALLIZED
POLYESTER FOIL W/GAS RESISTANT
INK.
C
8176
CHANGED CE TO 2809
MS
5-21-19
R
B
7847
IP RATING WAS 66
NJ
1-19-15
13.5.1.2 Labels