- 72 -
Term
Command
Description
Code128
SYMFOOT=Ca
Set footer character of Code128
=C,¥bb
a=0;
Disable
(*)
a=1; Enable
=C,c
bb; Hexadecimal code
c; Character
=C,[dd]
dd; ASCII code (¥00 to ¥1F)
When omitting “bb”, “c” and “dd”, those settings will be remained.
EAN128 SET=eM0 Disable
EAN128
SET=eM1
Enable EAN128
(*)
E128GS=a
Set Enable/Disable transmission of Control code [GS]
=a,¥bb
a=0; Disable
a=1; Enable
(*)
, Default: [GS]
=a,c
bb; Hexadecimal code
c; Character
=a,[dd]
dd; ASCII code (¥00 to ¥1F)
When omitting “bb”, “c” and “dd”, those settings will be remained.
DIGIT=eb,c
Set minimum (b) and maximum (c) digit numbers of EAN128
EDIT=eb,c
Output EAN128 data within a range of b-digits to c-digits
SYMHEAD=ea
Set header character of EAN128
=ea,¥bb
a=0;
Disable
(*)
a=1; Enable
=ea,c
bb; Hexadecimal code
c; Character
=ea,[dd]
dd; ASCII code (¥00 to ¥1F)
When omitting “bb”, “c” and “dd”, those settings will be remained.
SYMFOOT=ea
Set footer character of EAN128
=ea,¥bb
a=0;
Disable
(*)
a=1; Enable
=ea,c
bb; Hexadecimal code
c; Character
=ea,[dd]
dd; ASCII code (¥00 to ¥1F)
When omitting “bb”, “c” and “dd”, those settings will be remained.
Codabar SET=FM0 Disable
Codabar
SET=FM1
Enable Codabar, Disable C/D check
(*)
SET=FM2
Enable Codabar, Enable C/D check, Enable C/D transmission
SET=FM3
Enable Codabar, Enable C/D check, Disable C/D transmission
CODASS=0
Disable Codabar Start/Stop code transmission
CODASS=1
Enable Codabar Start/Stop code transmission
(*)
CODACS=0
Transmit Codabar Start/Stop code in lowecase
CODACS=1
Transmit Codabar Start/Stop code in lowercase in uppercase
(*)
CODACHK=a
Codabar Check digit calculation
a=0; Modulus 16
(*)
a=1; 7DR
DIGIT=Fb,c
Set minimum (b) and maximum (c) digit numbers of Codabar
EDIT=Fb,c
Output Codabar data within a range of b-digits to c-digits
SYMHEAD=Fa
Set header character of Codabar
=Fa,¥bb
a=0;
Disable
(*)
a=1; Enable
=Fa,c
bb; Hexadecimal code
c; Character
=Fa,[dd]
dd; ASCII code (¥00 to ¥1F)
When omitting “bb”, “c” and “dd”, those settings will be remained.
SYMFOOT=Fa
Set footer character of Codabar
=Fa,¥bb
a=0;
Disable
(*)
a=1; Enable
=Fa,c
bb; Hexadecimal code
c; Character
=Fa,[dd]
dd; ASCII code (¥00 to ¥1F)
When omitting “bb”, “c” and “dd”, those settings will be remained.
Summary of Contents for TFIR-31LAN series
Page 2: ...Update Information Edition Date Update Contents 1st edition 2012 06 13 New release...
Page 3: ...1...
Page 89: ...87 7 14 Table of Character code...
Page 91: ...89...
Page 101: ...99 Memorandom...
Page 102: ...100 Memorandom...
Page 103: ...101 Memorandom...
Page 104: ......