266 – SD Speed Demand
Cause
Corrective action
The signal for analog speed
demand is missing.
1. Switch on plant automation.
2. Contact Service.
321 – AL Wiring Cylinder A1
Cause
Corrective action
Short circuit fault in injector
wiring of cylinder A1 or injector
faulty.
1. Check wiring of injector concerned (→ Page 135).
2. Contact Service.
322 – AL Wiring Cylinder A2
Cause
Corrective action
Short circuit fault in injector
wiring of cylinder A2 or injector
faulty.
1. Check wiring of injector concerned (→ Page 135).
2. Contact Service.
323 – AL Wiring Cylinder A3
Cause
Corrective action
Short circuit fault in injector
wiring of cylinder A3 or injector
faulty.
1. Check wiring of injector concerned (→ Page 135).
2. Contact Service.
324 – AL Wiring Cylinder A4
Cause
Corrective action
Short circuit fault in injector
wiring of cylinder A4 or injector
faulty.
1. Check wiring of injector concerned (→ Page 135).
2. Contact Service.
325 – AL Wiring Cylinder A5
Cause
Corrective action
Short circuit fault in injector
wiring of cylinder A5 or injector
faulty.
1. Check wiring of injector concerned (→ Page 135).
2. Contact Service.
326 – AL Wiring Cylinder A6
Cause
Corrective action
Short circuit fault in injector
wiring of cylinder A6 or injector
faulty.
1. Check wiring of injector concerned (→ Page 135).
2. Contact Service.
MS150100/04E 2015-09
| Troubleshooting | 73
TIM-ID: 0000064702 - 001