7.15.2 Coolant level sensor – Check
Preconditions
☑
Plant has been put out of operation.
WARNING
Fuels are combustible and explosive.
Risk of fire and explosion!
• Avoid open flames, electrical sparks and ignition sources.
• Do not smoke.
• Wear protective clothing, protective gloves, and safety glasses / facial protection.
Checking coolant level sensor
1.
Drain coolant slowly.
Result:
Alarm must be issued after the preset time.
2.
Put plant into operation.
MS150118/01E 2015-05
| Task Description | 141
TIM-ID: 0000061051 - 001