365 – AL Stop SV-Wiring Ground
Red alarm; Self-restoring
Cause
Corrective action
Injector wiring fault.
u
Check wiring, replace wiring harness as necessary.
381 – AL Wiring TOP 1
Yellow alarm; warning
Cause
Corrective action
Short circuit or wire break on
transistor output 1 plant-side
(TOP 1).
u
Check wiring (→ Page 148).
382 – AL Wiring TOP 2
Yellow alarm; warning
Cause
Corrective action
Short circuit or wire break on
transistor output 2 plant-side
(TOP 2).
u
Check wiring (→ Page 148).
383 – AL Wiring TOP 3
Yellow alarm; warning
Cause
Corrective action
Short circuit or wire break on
transistor output 3 plant-side
(TOP 3).
u
Check wiring (→ Page 148).
384 – AL Wiring TOP 4
Yellow alarm; warning
Cause
Corrective action
Short circuit or wire break on
transistor output 4 plant-side
(TOP 4).
u
Check wiring (→ Page 148).
390 – AL MCR exceeded
Yellow alarm; warning
Cause
Corrective action
DBR/MCR function: MCR
(continuous maximum rate) was
exceeded.
u
-
MS150118/01E 2015-05
| Troubleshooting | 83
TIM-ID: 0000060724 - 001