Filling charge-air coolant
1.
Pour in treated coolant via the filling point on
the coolant line to the intercooler and via the
filler neck of the expansion tank until coolant
is visible at the marker plate.
2.
Install plug screws of filling points with new
sealing rings.
3.
Check proper condition of breather valve,
clean sealing faces if required.
4.
Position breather valve on filler neck and
close.
Final steps
1.
Start the engine and operate it at idle speed for some minutes.
2.
Check coolant level (→ Page 117).
M015565/03E 2016-02