8.21.2 Engine Control Unit – Plug connection check
Preconditions
☑
Engine is stopped and starting disabled.
Special tools, Material, Spare parts
Designation / Use
Part No.
Qty.
Pipe gripping pliers
F30017884
1
Checking Engine Control Unit
plug connections
1.
Check that all plug connections on the En-
gine Control Unit are properly seated using
pipe gripping pliers (3).
2.
Tighten loose bayonet union nuts (2) with
pipe gripping pliers (3) by turning them clock-
wise until they latch into place.
3.
Make sure that unassigned sockets are
closed off with cover caps.
4.
Contact Service if bayonet union nuts are de-
fective.
130 | Accessories for (Electronic) Engine Governor / Control System | M015565/03E 2016-02