Fault
code
Alarm text
Meaning
Task
359
OPEN_LOAD CYL.
B9
Disconnection in wiring to sole-
noid valve cylinder B9;
Misfiring
1. Check wiring.
2. Contact Service.
360
OPEN_LOAD CYL.
B10
Disconnection in wiring to sole-
noid valve cylinder B10;
Misfiring
1. Check wiring.
2. Contact Service.
361
POWER STAGE
FAIL 1
Defect in engine governor (sol-
enoid valve power stage)
Contact Service.
362
POWER STAGE
FAIL 2
Defect in engine governor (sol-
enoid valve power stage)
Contact Service.
363
STOP POWER
STAGE 1
Solenoid valve or wiring or en-
gine governor defective
automatic engine shutdown
1. Check wiring.
2. Try to re-start the engine (→ Page 45).
3. Contact Service.
364
STOP POWER
STAGE 2
Solenoid valve or wiring or en-
gine governor defective
automatic engine shutdown
1. Check wiring.
2. Try to re-start the engine (→ Page 45).
3. Contact Service.
365
STOP MV-WIRING Solenoid-valve wiring faulty;
automatic engine shutdown
1. Check wiring.
2. Try to re-start the engine (→ Page 45).
3. Contact Service.
381
TRAN.OUT1
PLANT DEF
Binary transistor output plant 1
defective
Contact Service.
382
TRAN.OUT2
PLANT DEF
Binary transistor output plant 2
defective
Contact Service.
383
TRAN.OUT3
PLANT DEF
Binary transistor output plant 3
defective
Contact Service.
384
TRAN.OUT4
PLANT DEF
Binary transistor output plant 4
defective
Contact Service.
385
TRAN.OUT5
PLANT DEF
Binary transistor output plant 5
defective
Contact Service.
386
TRAN.OUT6
PLANT DEF
Binary transistor output plant 6
defective
Contact Service.
66 | Troubleshooting | M015565/03E 2016-02
TIM-ID: 0000003158 - 001