3.2
Operating temperatures
Please note that the card’s lifetime, i.e., the MTTF (mean time to failure) may be reduced if operated
outside the extended temperature range.
Parameter
Min
Typ
Max
Unit
Normal operation
-30
+25
+85
°C
Automatic shutdown
1
<-40
>+85
°C
1.
Due to uncertainty in temperature measurement, a tolerance of ±3ºC on the stated shutdown
thresholds may occur.
Note that within the specified operating temperature ranges the unit temperature may vary to a great
extent depending on the operating mode, used frequency band, radio output power and current