1. Unscrew cap from the H-11199 Relubricating Tool.
2. Remove shaft from body and turn handle counter-clockwise to retract shaft until “O” ring and piston are
withdrawn into cap.
3. Insert a stick of Mueller Grease (H-853) into the body.
4. Replace and tighten cap.
5. Turn handle clockwise to force grease out of the nozzle opening.
6. Be sure the Luboseal
®
Stop is in either the FULLY OPEN or FULLY CLOSED position. This aligns the vertical
groove in the key with the grease port recess.
7. Remove the grease plug by using the hex wrench on Relubricating Tool handle. Screw tool nozzle into grease plug
threads as far as possible.
8. Turn the handle clockwise, forcing the grease into the vertical groove in the key. If immediate resistance is
encountered, probably the groove in the key is not aligned with the grease port. Turn the key slightly in either
direction until the grease begins to flow.
Relubricating Instructions
H-11199 Relubricating Tool
(continued)