Relubricating Instructions (continued)
• The amount of grease required to relubricate a Luboseal
®
Stop depends upon how hard the stop turns and how much
grease must be replaced. The table below shows the number of complete revolutions of the handle required to fully
relubricate each size of Luboseal
®
Stop. The table is based on the assumption that the stop has excessive port leakage
and that considerable grease has been dissipated.
•
NOTICE:
Do not over lubricate. If the condition of the
stop is not too bad, not as many turns of the handle
will be required as is indicated in the table. The service
technician, after a few trials, should be able to tell by
the feel of the handle whether or not the stop is filled
with grease. Be sure to use MUELLER GREASE
STICKS. They are made especially for MUELLER
STOPS.
9. Replace grease plug and tighten, using hex wrench on
Relubricating Tool handle.
By deviating from the above listed instructions, you will void any product warranty and release Mueller Co. and its affiliated entities from any and all liability
associated with the installation or use of this product. For details on the product’s warranty, terms, and conditions, please visit www.muellergas.com.
Phone: (800) 798-3131
© 2016 Mueller Co., LLC. All rights reserved.
Form 9664 05/16
Size of Stop
Revolutions of Handle to Fill Stop
3/4”
6
1”
7-1/2”
1-1/4”
10
1-1/2”
13-1/2”
2”
16
2-1/2”
25-1/2”