background image

Relubricating Instructions (continued)

•  The amount of grease required to relubricate a Luboseal

®

 Stop depends upon how hard the stop turns and how much  

    grease must be replaced. The table below shows the number of complete revolutions of the handle required to fully  

    relubricate each size of Luboseal

®

 Stop. The table is based on the assumption that the stop has excessive port leakage  

    and that considerable grease has been dissipated.

•  

NOTICE:

 Do not over lubricate. If the condition of the  

    stop is not too bad, not as many turns of the handle  

    will be required as is indicated in the table. The service  

    technician, after a few trials, should be able to tell by 

    the feel of the handle whether or not the stop is filled    

    with grease. Be sure to use MUELLER GREASE     

    STICKS. They are made especially for MUELLER  

    STOPS.
9. Replace grease plug and tighten, using hex wrench on  

    Relubricating Tool handle.

By deviating from the above listed instructions, you will void any product warranty and release Mueller Co. and its affiliated entities from any and all liability 
associated with the installation or use of this product. For details on the product’s warranty, terms, and conditions, please visit www.muellergas.com.

Phone: (800) 798-3131                     

© 2016 Mueller Co., LLC. All rights reserved.
Form 9664   05/16

Size of Stop

Revolutions of Handle to Fill Stop

3/4”

6

1”

7-1/2”

1-1/4”

10

1-1/2”

13-1/2”

2”

16

2-1/2”

25-1/2”