background image

6

Parts

HG-4 SUB-SURFACE DISCHARGE UNIT

REPLACEMENT PARTS

ID PART #

DESCRIPTION

1 HG-2201 

UV Protective Housing

2 546553

Dechlorination Sub Assembly

3 HG-S124

Latching Sub Assembly 

4 HG-A2006  TD Key 

5 HG-123100  Low-Pressure Relief Valve 

6 HG-S125

2" Cam-lock 

7 HG-S106 

Bottom Plate Sub Assembly 

8 HGA-BL 

Bluetooth Controller

HG-S106 

HG-4 Bottom Plate Sub Assembly 

HG-S124 

Latching Sub Assembly 

545729  

Centering Star 

HG-02125   1/4" x 1-1/4" Hex Bolt  
HG-13176   1/4" x 3/4" Phil Pan Screw 
HG-S128 

Relief Valve Sub Assembly 

HG-S126 

Insulation Star Sub Assembly 

546549  

HG-4 Top Plate Sub Assembly

HG-2201  

DIV 1021-R

HG-21088   HG-4 Name Plate
HG-V129  

Silver Thermal Insulation

HG-A2006   TD Key 
546372  

HG-4 Sample Port

HG-V116  

Bulkhead Union Brass

HG-13198   1/4 – 20 Threaded Knob
HG-V105  

1/4 Polyurethane tube

HG-123108   1/4" x 1/4" NPT Adaptor 
546531  

HG4 Sample Rod 

HG-V105  

1/4 Polyurethane tube

HG-S325 

HG-4 Valve Sub Assembly 

546550  

HG-4 Outlet Sub Assembly 

HG-S117  

HG-4 Bottom Plate Connection 

546522  

HG-4 Below-Grade Housing 

546526  

HG-4 Latching Rod 

HG-S318 

HG-4 Latching Solenoid 

546535  

HG-4 Main Nipple

546553  

HG-4 Dechlor Sub Assembly

4

1

5

7

6

2

3

8

Summary of Contents for Hydro-Guard HG-4

Page 1: ...d internal piping pressure has been relieved 4 Always use all necessary safety equipment and follow all recommended procedures when installing operating and maintaining the Hydro Guard Automatic Flush...

Page 2: ...ine feed Excavate a suitably sized ditch ensuring It is connected on one side to the utility s service line trench Remove any debris that might create uneven pressure on the Unit Compact the bottom of...

Page 3: ...enoids will come from the manufacturer with the plunger already magnetically latched open some zones will default to OPEN Follow the start up procedure for systems with DC Latching Solenoids Page 09 C...

Page 4: ...HG 4 Battery Replacement 1 Remove protective external cover and unlatch the cover of the Internal protective sleeve 2 Unscrew the cap off the watertight housing of the integrated Bluetooth programmin...

Page 5: ...Integrated Sample Station Included A standard feature on the HG 4 Sub Surface Discharge Unit Hydro Guard s Sample Port allows the end user to collect the sample You may wish to run a brief manual mod...

Page 6: ...an Screw HG S128 Relief Valve Sub Assembly HG S126 Insulation Star Sub Assembly 546549 HG 4 Top Plate Sub Assembly HG 2201 DIV 1021 R HG 21088 HG 4 Name Plate HG V129 Silver Thermal Insulation HG A200...

Page 7: ...7 NOTES...

Page 8: ...V Ltd All Rights Reserved The trademarks logos and service marks displayed in this document are the property of Mueller Water Products Inc its affiliates or other third parties Products marked with a...

Reviews: