9
Options
HG-6 FLUSHING SYSTEM
HYDRO-GUARD KEY FEATURES, OPTIONS AND UPGRADES
Integrated Sample Station
Increase your control of
chlorine or chloramines residual
maintenance through the
integrated sample station. The
built-in Sample Valve is located
inside the top lid of the HG-6
(this feature in an option on the
HG-6 / Basic). Make sure to
firmly grip the tubing and then
turn the ball valve, and collect
your sample. You may wish to
run a brief manual-mode flush
prior to the collection in order to
ensure water indicative of the
main-line water quality is being
sampled. Generally a two-minute
flush is sufficient. Track your
residual levels and alter
flushing frequency and/or
duration in order to maximize
water conservation.
From the integrated sample
stations to dechlorination
upgrades, your Hydro-Guard
Device offers an outstanding
return on investment.
The following is a brief
overview and introduction to
our options.
Dechlorination
The HG-6 Hydrant-Based
Flushing System has a built-
in Dechlorination chamber
located in the base of the unit.
By removing the Dechlorination
Chamber access door, locate
opposite of the inlet piping and
hydrant adapter, pull out the
chamber and load it with sodium
sulfite or ascorbic acid tablets.
Dechlorination takes place as a
portion of the discharged water
passes through this chamber. This
action creates a concentrated
dechlorination solution that then
mixes with the non-directly treated
portion of the discharged water.