6. DIRECT VENTING WITH FACTORY BUILT GREASE DUCT
6.1 DIRECT VENT REQUIREMENTS USING FACTORY BUILT GREASE DUCT
•
Oven installations utilizing direct vent grease duct must comply with NFPA 96
•
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE
•
Factory built grease duct assemblies must be listed to UL 1978
•
Example grease duct: Metal Fab G-Series www.metal-fabinc.com
•
Ideal for complicated runs, long lengths or horizontal runs
•
Weld grease duct starter piece to oven using
Direct Vent Flue Adaptor - part# GDV
•
Chimney must be installed per chimney manufacturer’s installation instructions
•
Chimney must terminate to an approved chimney cap with spark arrestor (screen mesh)
•
Chimney lengths 25 feet or longer may require an exhaust fan. The Enervex GSV series fan is listed
for use with a wood burning pizza oven see: http://www.greasefans.com
•
Applicable for any menus including cooking meat
6.2 ADDITIONAL REQUIREMENTS FOR CANADA
•
The use of smoke detectors is highly recommended
•
The chimney connector shall not pass through an attic, roof space, closet floor, ceiling, or similar
concealed space. Where passage through a wall or partition of combustible construction is desired,
the installation shall conform with CAN/CSA-B365
6.3 OVEN FLUE OUTLET
•
Flue size: 8” round (internal diameter)
•
Flue location: on top of oven centered above arch, 7 3/8”
(+/- 1”) behind the front panel
6.4 CONNECTING FACTORY BUILT
GREASE DUCT TO OVEN
Mugnaini offers an optional Direct Vent Flue Adaptor for
installation in the factory. Part# GDV has a 2” weldable stainless
stub for a field welded grease duct adaptor.
Part # GDV
Grease duct adaptor