background image

 

M0701.docx  |  

Rev 1.5  |  Modified on 26/03/2021

 

|  © Remote Control Technologies Pty Ltd  

 

11  |  16 

 

11387 KIT PARK BRAKE WARNING WITH ONE SWITCH AND NO OVERRIDE 

 

PART NO. 

DESCRIPTION 

QUANTITY 

INCLUDED 

PARTS 

SUGGESTED 

SPARES 

6812 

Proximity Switches 

11377 

Control unit to suit 11387 

0658 

Door Open Warning Label 

– 

5054 

Park Brake Switch 

– 

0821 

Terminal F/Spade Blue 

– 

0825 

Terminal Blue 5.3 mm Hole 

– 

0826 

Terminal Blue 6.6 mm Hole 

– 

9393 

LED M/V Red 2T Flashing 

– 

11378 

Loom To Suit 11387 

– 

5343 

System Override Label 

– 

– 

3543 

Key Switch Head Stay Put L/H 

– 

– 

5510 

Switch Body with 1 x N/C Contact 

– 

– 

 
 

TECHNICAL SPECIFICATIONS 

 

Dimensions, control unit only

 

Length: 119 mm  |  Width: 80 mm  |  Height/Depth: 65 mm

 

Dimensions, boxed for freight

 

Length: 300 mm  |  Width: 200 mm  |  Height/Depth: 180 mm

 

Weight, control unit only

 

255 g

 

Weight, including harness / 
packaging for freight

 

2 kg

 

Input nominal voltage

 

12 to 24 V DC

 

Min & Max Input Voltage 

8 to 35 V DC 

System current rating: 

10 A continuous 

Operating temperature: 

−10 to +65 °C 

Connection types 

12-pin Deutsch receptacle 

Inputs 

Environmental rating: 

IP65 

Circuit protection 

External control, reverse polarity protection 

Enclosure material 

Polycarbonate 

 
 

 

 

Summary of Contents for 11377

Page 1: ...PRODUCT MANUAL PARK BRAKE WARNING SYSTEM 12 24 VOLTS Part No 11377 11386 11387 ...

Page 2: ...t 5 RCT provides the document to you on an as is basis RCT is not required to provide any updates to this version of the document RCT may make any change amendment or modification to the contents in this document without notice to you 6 RCT takes a best endeavour basis to ensure that the contents in this document are accurate complete and reliable RCT does not warrant that the document will contin...

Page 3: ...ION 6 INSTALLATION INSTRUCTIONS 6 WIRING CONNECTIONS 6 EXTERNAL WIRING DIAGRAM 8 LOOM DIAGRAM 474s 8 EXTERNAL WIRING DIAGRAM 474u 9 CALIBRATION 10 SERVICE INFORMATION 10 SERVICE SCHEDULE 10 SERVICE PROCEDURE 10 PARTS LIST 10 11386 KIT PARK BRAKE WARNING 10 11387 KIT PARK BRAKE WARNING WITH ONE SWITCH AND NO OVERRIDE 11 TECHNICAL SPECIFICATIONS 11 COMPLIANCE AND STANDARDS 12 TROUBLESHOOTING 12 GLOS...

Page 4: ... protect the machine and other equipment in the area Do not operate any machine with a known fault and report all findings to the supervisor in writing Test and operate machine as per machine OEM and site procedures Read and understand machine and site specific operational and testing instructions PRODUCT Before applying power to the equipment the user repairer installer must read all product inst...

Page 5: ...oltage 12 to 24 volts Compact and robust design Environmentally sealed IP65 Audio and visual indicators Door sensing Park brake sensing Self test outputs at startup Customised circuitry Override switch Protects personnel working on and near machine Helps prevent unattended machine run away accidents OPERATION AND USE When the park brake warning system is first powered up the alarms will self test ...

Page 6: ...rom heat and abrasion and any other excess damage that may occur with extended vehicle operation When securing the wiring to the OEM wiring ensure that the loom is away from moving vehicle parts which could lead to loom damage 3 Mount the LED on the instrument panel in the cabin clear view of the operator WIRING CONNECTIONS NO COLOUR FUNCTIONS DESCRIPTION 1 Red Ignition Input Keyed override switch...

Page 7: ... Pin 2 Pin 2 Black Pin 3 Pin 10 White Pin 4 Pin 3 Green Pin 5 Pin 6 Blue Pin 6 Pin 7 Blue Pin 7 Pin 8 Grey Pin 8 Not connected All other pins on the 12 pin connector are not connected and should be sealed using the blocking contacts The following parts are required when upgrading the old control unit PART NO DESCRIPTION QTY 2022 12 socket connector supplied separately 1 1959 Lock wedge 12 socket s...

Page 8: ... D E F G H B A C D E F G H 1 2 3 4 5 6 7 8 9 10 11 12 A4 COPYRIGHT ALL RIGHTS RESERVED This drawing is the property of REMOTE CONTROL TECHNOLOGIES PTY LTD RCT and is not to be copied or used in whole or in part for any purpose without the express authority of RCT The drawing is to be returned to RCT on demand PARK BRAKE WARNING LOOM LOOM CONFIGURATION www rct net au UNCONTROLLED DOCUMENT REV 0 DWG...

Page 9: ... net au N12596 1 2 3 4 5 6 7 8 9 10 11 12 B A C D E F G H B A C D E F G H 1 2 3 4 5 6 7 8 9 10 11 12 A4 COPYRIGHT ALL RIGHTS RESERVED This drawing is the property of REMOTE CONTROL TECHNOLOGIES PTY LTD RCT and is not to be copied or used in whole or in part for any purpose without the express authority of RCT The drawing is to be returned to RCT on demand PARK BRAKE WARNING SYSTEM EXTERNA WIRING w...

Page 10: ...ual for instructions on the operation of each function and checking the controller for maintenance or repairs that may be required to keep it functional and operational b For any problems found when testing refer to the Troubleshooting section of this manual PARTS LIST 11386 KIT PARK BRAKE WARNING PART NO DESCRIPTION QUANTITY INCLUDED PARTS SUGGESTED SPARES 6812 Proximity Switches 2 1 11377 Contro...

Page 11: ...7 1 5343 System Override Label 3543 Key Switch Head Stay Put L H 5510 Switch Body with 1 x N C Contact TECHNICAL SPECIFICATIONS Dimensions control unit only Length 119 mm Width 80 mm Height Depth 65 mm Dimensions boxed for freight Length 300 mm Width 200 mm Height Depth 180 mm Weight control unit only 255 g Weight including harness packaging for freight 2 kg Input nominal voltage 12 to 24 V DC Min...

Page 12: ...s Emissions for Residential Commercial and Light Industrial Environments EU IEC 61000 6 1 2005 Electromagnetic Compatibility EMC Part 6 1 Generic Standards Immunity for Residential Commercial and Light Industrial Environments IEC 61000 6 3 2006 A1 2010 Electromagnetic Compatibility EMC Part 6 3 Generic Standards Emissions for Residential Commercial and Light Industrial Environments RoHS 2 Directiv...

Page 13: ...r DC Direct Current PLC Programmable Logic Controller E G For example POT Potentiometer ETR Energised To Run PPM Pulses Per Metre ETS Energised To Stop PWM Pulse Width Modulation ESD Engine Shutdown PWR Power FET Field Effect Transistor Rev Revision GND Ground RF Radio Frequency H Hours RH Relative Humidity HEX Hexadecimal Numbering System RPM Revolutions per minute ID Identity RX Receiver i e Tha...

Page 14: ...14 16 M0701 docx Rev 1 5 Modified on 26 03 2021 Remote Control Technologies Pty Ltd NOTES ...

Page 15: ...M0701 docx Rev 1 5 Modified on 26 03 2021 Remote Control Technologies Pty Ltd 15 16 NOTES ...

Page 16: ...Discover more www rct global com sales rct global com AUSTRALIA 61 0 8 9353 6577 AFRICA 27 0 83 292 4246 CANADA 1 705 590 4001 RUSSIA CIS 7 910 411 11 74 SOUTH AMERICA 56 3 5229 9409 USA 1 801 938 9214 ...

Reviews: