background image

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

PRODUCT MANUAL 

IDLE TIMER ETR CONTROLLER 12/24 V

 

      

Part No. 11450 | 11452 | 11951 | 12286 

Summary of Contents for 11450

Page 1: ...PRODUCT MANUAL IDLE TIMER ETR CONTROLLER 12 24 V Part No 11450 11452 11951 12286 ...

Page 2: ...t 5 RCT provides the document to you on an as is basis RCT is not required to provide any updates to this version of the document RCT may make any change amendment or modification to the contents in this document without notice to you 6 RCT takes a best endeavour basis to ensure that the contents in this document are accurate complete and reliable RCT does not warrant that the document will contin...

Page 3: ...9 Wiring Diagrams 10 External Wiring Diagram 476l 10 Loom to Suit Idle Time Controller 476m 11 Suggested Wiring to Suit Komatsu Machines 513c 12 Suggested Wiring to Suit Late Model Komatsu Machines 513l 13 External Wiring to Suit Shutdown When Shutdown Switch Activated With Key On Or Off 514z 14 Calibration 15 11450 Idle Timer Controller 15 Calibration Mode 15 Changing Idle Time Value 15 Service I...

Page 4: ... protect the machine and other equipment in the area Do not operate any machine with a known fault and report all findings to the supervisor in writing Test and operate machine as per machine OEM and site procedures Read and understand machine and site specific operational and testing instructions Product Before applying power to the equipment the user repairer installer must read all product inst...

Page 5: ...hat require oil for bearing lubrication the high temperatures of the turbochargers must be dissipated before the engine is switched off Features and Functions Multi voltage 12 24 V Selectable idle time cycle provides flexibility in shutdown time from 1 12 minutes in one minute increments Suitable for Energised To Run ETR systems Steering accumulator bleed down output Park brake applied detection G...

Page 6: ...the off position 2 If the key is switched off at any time with the park brake released the machine will shut down immediately and the alarm will sound 3 If an operator is required to mobilise the machine whilst the key is switched to the off position and the machine is in idle down mode the key must be returned to the run position before the park brake is released Ground Level Shutdown Optional If...

Page 7: ... existing OEM wire no 326 from the C terminal at the key switch and connect to the purple wire pin 9 from the controller Wiring Connections No Colour Function Description 1 Red Battery VE Connect to the permanent battery supply at the key switch supply 12 24 Vdc 2 Black Ground Earth ground 3 Yellow Blue Output 1 Ignition Output Connect to the OEM ignition wires previously disconnected from the ign...

Page 8: ...h the plug and pin to the corresponding 12 pin Deutsch connection Old Idle Timer 9087 Plug Connections New Idle Timer 11450 12 Pin Deutsch Connections Plug A pin 1 BK 4 Pin 2 Plug A pin 2 YL BU 4 Pin 3 Plug A pin 3 RD 4 Pin 1 Plug A pin 4 OR 4 Pin 5 Plug A pin 5 PU 4 Pin 9 Plug B pin 1 PK 4 Pin 8 Plug B pin 2 PK 4 Pin 11 Plug B pin 3 BK 4 Pin 4 Plug B pin 4 YL 4 Pin 12 If there are any concerns wh...

Page 9: ... Old Idle Timer 5965 Plug Connections New Idle Timer 11450 12 Pin Deutsch Connections Plug A pin 1 BK 4 Pin 2 Plug A pin 2 YL BU 4 Pin 3 Plug A pin 3 RD 4 Pin 1 Plug A pin 4 OR 4 Pin 5 Plug A pin 5 PU 4 Pin 9 Plug B pin 1 Positive Output from Park Brake Switch Pin 6 Plug B pin 2 Pin 8 Plug B pin 3 Connect to Ground Pin 2 or Pin 11 Plug B pin 4 Pin 11 Plug B pin 5 Pin 12 Plug B pin 6 Pin 4 Plug B p...

Page 10: ...r used in whole or in part for any purpose without the express authority of RCT The drawing is to be returned to RCT on demand IDLE TIMER CONTROL EXTERNAL WIRING www rct net au UNCONTROLLED DOCUMENT REV 2 DWG No 476l STATUS NTS SCALE Released SHEET 1 of 1 BY EY DRN EH DATE 26 04 13 APPD DAS DATE 26 04 13 STOCK CODE MH EC MV ER PART NO 11450 3rd ANGLE PROJECTION ALL DIMENSIONS IN MILLIMETERS REV ZO...

Page 11: ...0 11 12 B A C D E F G H B A C D E F G H 1 2 3 4 5 6 7 8 9 10 11 12 A4 COPYRIGHT ALL RIGHTS RESERVED This drawing is the property of REMOTE CONTROL TECHNOLOGIES PTY LTD RCT and is not to be copied or used in whole or in part for any purpose without the express authority of RCT The drawing is to be returned to RCT on demand LOOM TO SUIT IDLE TIMER CONTROLLER ENERGISED TO RUN ETR LOOM CONFIGURATION w...

Page 12: ...RESERVED This drawing is the property of REMOTE CONTROL TECHNOLOGIES PTY LTD RCT and is not to be copied or used in whole or in part for any purpose without the express authority of RCT The drawing is to be returned to RCT on demand IDLE TIMER CONTROL 11450 TO SUIT KOMATSU MACHINES SUGGESTED EXTERNAL WIRING www rct net au UNCONTROLLED DOCUMENT REV 3 DWG No 513c STATUS NTS SCALE Released SHEET 1 of...

Page 13: ...S RESERVED This drawing is the property of REMOTE CONTROL TECHNOLOGIES PTY LTD RCT and is not to be copied or used in whole or in part for any purpose without the express authority of RCT The drawing is to be returned to RCT on demand IDLE TIMER CONTROL 11450 TO SUIT LATE MODEL KOMATSU MACHINES SUGGESTED EXTERNAL WIRING www rct net au UNCONTROLLED DOCUMENT REV 3 DWG No 513l STATUS NTS SCALE Releas...

Page 14: ... drawing is the property of REMOTE CONTROL TECHNOLOGIES PTY LTD RCT and is not to be copied or used in whole or in part for any purpose without the express authority of RCT The drawing is to be returned to RCT on demand IDLE CONTROL TIMER 11450 WITH PARK BRAKE INPUT AND OPTIONAL GROUND LEVEL SHUTDOWN SWTICHES EXTERNAL WIRING www rct net au UNCONTROLLED DOCUMENT REV 4 DWG No 514z STATUS NTS SCALE R...

Page 15: ...ead the entire procedure before starting To enter calibration mode 1 Hold the engine shutdown switch in the active position 2 Turn on ignition 3 Turn off ignition 4 Release the engine shutdown switch 5 The cycle LED will be flashing If performed correctly the device will now be in calibration mode This is indicated by all device status indicators flashing very fast Note The calibration mode will t...

Page 16: ... connections and looms c Switches 2 Perform a system test as per the Operation and Use section of this manual for the operation of the controller Parts List 11452 Idle Timer Kit Part No Description Quantity Included Parts Suggested Parts 11450 Idle Timer Controller 1 1 11451 Loom to suit 11450 Idle Timer Controller 1 12286 Idle Timer Kit to suit Komatsu Part No Description Quantity Included Parts ...

Page 17: ...quired by the relevant regulatory bodies depending on the market and location This product currently complies with the following ACMA IEC 61000 6 1 2005 Electromagnetic Compatibility EMC Part 6 1 Generic Standards Immunity for Residential Commercial and Light Industrial Environments IEC 61000 6 3 2006 A1 2010 Electromagnetic Compatibility EMC Part 6 3 Generic Standards Emissions for Residential Co...

Page 18: ...r dc direct current PLC Programmable Logic Controller E G For example POT Potentiometer ETR Energised To Run PPM Pulses Per Metre ETS Energised To Stop PWM Pulse Width Modulation ESD Engine Shutdown PWR Power FET Field Effect Transistor Rev Revision GND Ground RF Radio Frequency H Hours RH Relative Humidity HEX Hexadecimal Numbering System RPM Revolutions per minute ID Identity RX Receiver i e Tha...

Page 19: ...M0712 docx Rev 4 1 Modified on 13 05 2021 Remote Control Technologies Pty Ltd 19 20 Notes ...

Page 20: ...Discover more www rct global com sales rct global com AUSTRALIA 61 0 8 9353 6577 AFRICA 27 0 83 292 4246 CANADA 1 705 590 4001 RUSSIA CIS 7 910 411 11 74 SOUTH AMERICA 56 3 5229 9409 USA 1 801 938 9214 ...

Reviews: