MultiMobile Owner’s Manual
74
S9=1-255
S9 sets the time, in tenths of a second, that the
carrier must be present before the modem considers
it valid and turns on RLSD. The factory default is
006.
S10=1-255
S10 sets the length of time, in tenths of a second,
that the modem waits before hanging up after a loss
of carrier. The factory default is 014.
S11=50-255
S11 sets the DTMF duration and inter digit delay in
mini-seconds, in DTMF touch tone dialing. The
factory default is 095.
S12=0-255
S12 defines the maximum period, in 2-hundredths of
a second, allowed between consecutive
asynchronous escape character “+” (plus) for the
escape sequence to be considered valid. The
factory default is 050.
S18=0-255
S18 sets the length of time, in seconds, that the
modem conducts a test (commanded by “AT&Tn”)
before returning to command mode. If this register
value is zero, the test automatically terminates, the
test progress must be ended by issuing “AT&T0” or
“ATH” commands. The factory default is 000.
S25=0-225
S25 sets the length of time, in hundredths of a
second, that the modem ignores DTR for before
hanging up. The factory default setting is 005.