background image

 

GENERAL SPECIFICATIONS                                                                                                                   
Measuring Method                : Dual integration method with true rms reading 
Measuring Function            : DC Voltage, AC Voltage, Resistance, Continuity Check, 

Diode Test with Data Hold & Auto Power Off functions.             

Display                                    : LCD, max. reading of 3200 with bar graph 
Polarity                                    : Automatic (

) negative indication 

Over Range Indication        : "OL" mark on LCD readout 
Low Battery Indication        : "B" mark is displayed when the battery voltage drops 
                                                        below operating voltage 
Sampling                                : 2 times/second 
Operating Temperature      : 0

40

80%RH (non-condensing) 

Storage Temperature          : 

20

60

70%RH (non-condensing) 

Power Supply                        : LR-44 x 2     
Power Consumption            : Approx. 12mW 
Size & Weight                        : 60(H)x110(W)x9.5(D)mm, approx. 60g 
Accessories                            : Book Type Cover Case ……….1, Instruction Manual ………… 1   

Battery ……………………….. 2 
 

 

NAME & EXPLANATION OF EACH PART                                                                                                                                         

① 

ROTARY SWITCH    : Power On/Off, Measuring Ranges   

for DCV, ACV, Resistance, Diode Test                             

60

   

and Continuity Check.                       

② 

FUNCTION KEY      : When the position of rotary switch is   

at 

Ω

)))   

+, can change from 

Ω

./ 

))) / 

+ by turns.                                                                                     

③ 

DATA HOLD KEY    : By pressing this key, the display   

value will be hold (DH sign will appear) 
and it will be released by pressing once   
again. (DH sign will disappear). 

④ 

DISPLAY                    : LCD display for measuring value,   

annunciator, battery sign, etc. 

⑤ 

TEST LEADS            : Red is for 

  polarity and Black is for 

.   

⑥ 

BATTERY COMPARTMENT (Rear Side) 

 

 

MEASURING RANGES & ACCURACY

   

  (23

℃±

5

,<80%RH non-condensing)

                                                                                                                               

 

Function 

Range 

Accuracy 

Input Impedance  Max. Input Voltage 

 
 

DCV 

 
 
 

320.0mV 

±

(1.3%rdg

±

3dgt) 

>1000M

Ω

 

 
 
AC/DC 500Vrms 
 
 

3.200V 

±

(0.7%rdg

±

3dgt) 

approx. 11M

Ω

 

32.00V 
320.0V 
500V 

 

±

(1.3%rdg

±

3dgt) 

 

 
approx. 10M

Ω

 

 

 

ACV 

(40Hz~1kHz) 

3.200V 

±

(1.3%rdg

±

3dgt) 

approx. 11M

Ω

 

 
 

AC/DC 500Vrms 

 

32.00V 
320.0V 
500V 

   

  ±(2.3%rdg±6dgt) 

 
approx. 10M

Ω

 

 

 

Function 

Range 

Accuracy 

Testing Current  Max. Input Protection 

 
 

OHM 

 
 
 

320.0

Ω

 

±

(2%rdg

±

5dgt) 

<0.7mA 

 
 

500Vrms 

 
 
 

3.200k

Ω

 

 

±

(2%rdg

±

3dgt) 

 

<0.13mA 

32.00k

Ω

 

<13

μ

320.0k

Ω

 

<1.3

μ

3.200M

Ω

 

±

(6%rdg

±

4dgt) 

<0.13

μ

 

32.00M

Ω

 

±

(10%rdg

±

10dgt) 

   

Diode Test 

  3.200V 

±

(10%rdg

±

3dgt) 

  approx.. 0.7mA 

         

500Vrms 

Continuity 
Check 

320.0

Ω

 

Continuity Beeper, 

<approx. 20

Ω

 

  approx.. 0.7mA 

         

500Vrms

 

Reviews: