background image

 

                                                        

 

 

 

 

  INSTALLATION & OPERATING  

MANUAL 

                    FSFCA Universal Mount Fan Coil 
                             12,000-60,000 BTUH 

 

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                  
 
 
 
 
 
 
 
 
 
 
 
 
   

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

GENERAL 

Read the entire contents of this manual 
before beginning installation. Multiaqua 
assumes no responsibility for equipment 
installed contradictory to any code 
requirement or installation instructions. 

   The components of this fan coil have 
been inspected at the factory and readied 
for shipment. Upon receiving the 
shipment a visual inspection of the 
packaging must be performed.  

   If any damage to the packaging is 
discovered, an inspection of the 
components must be performed and 
noted on the delivery documents. If 
component damage is found a damage 
claim must be filed by the receiving party 
against the delivery party immediately. 

  This product is designed and 
manufactured to permit installation in 
accordance with national codes. It is the 
installer’s responsibility to install the 
product in accordance with national 
codes and/or prevailing local codes and 
regulations.  
  Care must be taken to ensure the 
structural integrity of the supporting 
members, clearances and provisions for 
servicing, power supply, coil connections 
and/or condensate removal. Before the 
installation ensure the structural strength 
of the supporting members is sufficient. 
See 

Figure 1

 for hanging weights of the 

fan coils.  
 This unit is designed to be installed in a 
 

-------------------------------------- CAUTION -------------------------------------- 

Care must be taken when handling sheet metal. Sheet metal parts have sharp edges and could 
cause injury.  

horizontal or vertical configuration. Fan coil 
can be mounted on a wall or ceiling. See 

Figure 2

 for fan coil and mounting bracket 

dimensions. 

FAN COIL  

APPROXIMATED  

MODEL NUMBER 

WEIGHTS (lbs.) 

FSFCA-04-1-U 

88.00 

FSFCA-06-1-U 

90.20 

FSFCA-08-1-U 

96.80 

FSFCA-12-1-U 

143.00 

FSFCA-16-1-U 

154.00 

FSFCA-20-1-U 

256.20 

   
    

                           Figure 1 

Summary of Contents for FSFCA

Page 1: ...FSFCA Ductless Direct Expansion Fan Coil Rev 1 1 ...

Page 2: ...allation in accordance with national codes It is the installer s responsibility to install the product in accordance with national codes and or prevailing local codes and regulations Care must be taken to ensure the structural integrity of the supporting members clearances and provisions for servicing power supply coil connections and or condensate removal Before the installation ensure the struct...

Page 3: ...nt Fan Coil 12 000 60 000 BTUH FSFCA Mounting Bracket Dimensions in Model Number A B FSFCA 04 1 U 36 49 13 00 FSFCA 06 1 U 36 49 13 00 FSFCA 08 1 U 36 49 13 00 FSFCA 12 1 U 48 30 13 00 FSFCA 16 1 U 71 97 13 00 FSFCA 20 1 U 71 97 13 00 Figure 2 A B BACK ...

Page 4: ...the right hand side bottom and right side rear Figure 4 5 See next page for access hole dimensions Figures 4 and 5 3 Remove mounting brackets from both sides of unit Figure 6 4 Prepare mounting bolts for mounting unit under ceiling or on a wall at the distances provided in Figure 2 Page 3 5 Select a location that permits even air flow throughout the room 6 Select a location that has enough service...

Page 5: ...5 INSTALLATION OPERATING MANUAL FSFCA Universal Mount Fan Coil 12 000 60 000 BTUH Piping Locations ...

Page 6: ...n line with each other before tightening nut to allow concentric seating of tube onto flare nut as to prevent leakage Ensure the unit s flared connection is supported with a backup wrench when removing or tightening any flair nuts 10 If installing a TXV at the condenser ensure that the liquid line is properly insulated all the way to the evaporator 11 Connect the field drain line to the clear drai...

Reviews: