OPERATION

AC/DC VOLTAGE MEASUREMENT

DC VOLTAGE MEASUREMENT

AC VOLTAGE MEASUREMENT

EF MEASUREMENT

AUTO FUNCTION MEASUREMENT

•  Press SELECT to switch between resistance, AC/DC 

voltage, continuity buzzer and diode measurement modes. 

Press and hold to exit “sleep” mode. 

•  Press HOLD to enter and exit hold mode (except under auto 

scan mode).  

•  Press and hold the HOLD button, the meter displays 

H

 automatically holds the value currently displayed for 

approximately 6 secs. If the Meter enters “sleep” while in 

hold mode, the meter will still be in the hold mode when it is 

powered back on. 

•  The MAX/MIN mode stores minimum (MIN) and maximum 

(MAX) input values (except under auto scan mode). Manual 

ranging is default when you select this function. 

•  Press MAX/MIN button to switch between MAX, MIN, and 

MAX/MIN options. 

•  If under both HOLD mode and MAX/MIN mode, exit HOLD 

mode first then press and hold MAX/MIN for more than 1 

second to exit MAX/MIN mode.

•  Press   BACKLIGHT to turn the display backlight and test 

lead LED on. Press again to turn the display backlight and 

test lead light off. It will automatically turn off after 1 minute.

•  Auto power off is set to approximately 10 minutes to 

preserve battery life if no button is pressed. The meter can 

be activated again by pressing any button, following which it 

returns to the previously active function. 

•  Before making any measurement the meter test input 

terminal has to be exposed by pressing down and twisting 

the red cover counter clockwise.

•  Connect the supplied COM test lead to the connector on the 

end of the meter.

•  When measurement is complete restore the cover by 

twisting it clockwise to protect the terminal.

•  Set the mode to V

~

. Auto measurement mode is the default.

•  This mode can measure AC voltage and DC voltage.

•  Connect the test leads with the object being measured. The 

measured value shows on the display.

•  When voltage measurement has been completed, 

disconnect the connection from  the test leads and the circuit 

under test, and remove the testing leads from the input 

terminal of the meter.

Note:

 The threshold voltage of AC voltage is around 400mV

.

•  Set the mode to V

~

•  Press SELECT to set DC voltage measurement mode.

•  Connect the test leads with the object being measured. 

•  The measured value shows on the display.

•  When voltage measurement has been completed, 

disconnect the connection between the testing leads and 

the circuit under test, and remove the testing leads from the 

input terminal of the meter.

Note:

 Do not input greater than 300V voltage although it is 

possible to measure higher voltage, accuracy and safety are 

reduced.

•  Set the mode to V

~

•  Press SELECT to set AC voltage measurement mode.

•  Connect the test leads with the object being measured. 

•  The measured value shows on the display.

•  When voltage measurement has been completed, 

disconnect the connection between the testing leads and 

the circuit under test, and remove the testing leads from the 

input terminal of the meter.

Note:

 Do not input greater than 300V voltage to avoid damage 

to the meter. The threshold voltage of AC voltage is around 

400mV.

•  Set the mode to V

~

EF and remove the test lead from the 

input terminal.

•  Press SELECT to set EF measurement mode.

•  Place the red tip probe toward the object being measured. 

•  The measured value shows on the display.

•  Set the mode to Ω

   

•  Auto measurement mode is the default, in which the meter 

can measure Resistance, Diode, Continuity and Capacitance 

automatically. 

•  For best accuracy, remove the component being measured 

from the circuit before measurement.

•  Connect the test leads with the object being measured.

•  The measured value shows on the display.

•  When measurement has been completed, disconnect the 

connection between the testing leads and the item under 

test, and remove the testing leads from the input terminal of 

the meter.

Note:

 To avoid damages to the Meter or to the devices under 

test, disconnect circuit power and discharge all the high-voltage 

capacitors before measurement.

Note:

 Under auto measurement mode, when measuring  

Resistance of <15Ω or >10MΩ or Capacitance of <400pF or 

>1mF the Meter may display an inaccurate value. Use the 

dedicated mode to avoid this for these values.