TROUBLESHOOTING

CLEANING

• 

Cleaning should only be done when the iron is switched off and at room 

temperature.

• 

The irons and station case may be cleaned with a damp cloth and a small amount 

of liquid detergent if necessary.

• 

Never submerse the soldering irons in liquid or allow any liquid to enter the station 

casing.

• 

Do not use any chemicals, abrasives or solvents that could damage the soldering 

irons or station casing.

• 

If the symbol

displays, the tool attached to the channel currently active is 

failing to reach the required temperature. The tool heater element may have failed 

and requires replacement, or replace the complete tool.

SPECIFICATIONS

Tool Model

Soldering Pen

Soldering 

Tweezers

Desoldering Gun

Hot Air Tool

Rated Voltage

24V

12V

24V

As Input

Heating Power

130W

100W

150W heating/

15W vacuum

550W heating/

25W vacuum

Temperature 

Range

150-500

o

C

150-500

o

C

300-500

o

C

150-500

o

C

Temp Stability

±5

o

C

±2

o

C

±2

o

C

±2

o

C

Air Flow

-

-

-

5-23 litres/min

Heater Core

Integrated Element

Temperature 

Sensor

Thermocouple

Sleep Mode

• 

S

witch to the channel you wish to chang

e. 

Note:

 Only Channels 1 and 2 can have a sleep setting.

•  To switch the sleep duration from the factory default of no sleep, then 

enter the calibration mode by p

ress and holding the LOCK/VACUUM button 

and Button 1 for 3 seconds.

• 

Do not enter any calibration value and press Button 1 to enter sleep setting mode.

• 

SLP and the tool identifier connected to the channel chosen will display on the LH 

side of the LCD.

• 

Press UP or DOWN buttons to increase or decrease the time (in minutes) before 

that channel will enter sleep mode.

Note: 

Sleep default temperature is set to 200

o

C so when the working temperature is 

greater it will reduce to 200

o

C, but if the working temperature is less it will remain at the 

working temperature.

• 

Press Button 1 to resume from sleep mode.

• 

The method is the same for either channel.

Summary of Contents for MP740029

Page 1: ...1 4 in 1 Rework Soldering Station Model MP740029...

Page 2: ...arts before the soldering tip has cooled down completely Do not use the product near flammable items Turn the power off when this product is not in use The soldering iron must be placed on its stand w...

Page 3: ...e Error Indicator Power Display Bar Indicator Mode Indicator Tool Indicator Air Volume Display Air Output indicator Power Switch Channel 1 Indicator Channel 1 Indicator Channel 3 Indicator Channel 1 L...

Page 4: ...isplayed and the channel cannot be activated Channel 3 is used for the hot air gun tool only and has additional displays to indicate when the air fan is on and the airflow rate Temperature Adjustment...

Page 5: ...lock the channel so settings cannot be changed press and hold the LOCK VACUUM button until the padlock display changes mode Key Beep Function To switch the key sound feature on or off press and hold...

Page 6: ...ith a temperature measurement meter set up appropriately Press and hold the LOCK VACUUM button and Button 1 for 3 seconds to enter calibration mode With a temperature set e g 350o C measure the actual...

Page 7: ...mperature Range 150 500o C 150 500o C 300 500o C 150 500o C Temp Stability 5o C 2o C 2o C 2o C Air Flow 5 23 litres min Heater Core Integrated Element Temperature Sensor Thermocouple Sleep Mode Switch...

Page 8: ...y and recycling of the materials used Contact your local authority for details of recycling schemes in your area Made in China LS12 2QQ Man Rev 1 1 Mains Power 230V 50Hz Power 900W Max Sleep Mode Temp...