7
TEMPERATURE COMPENSATION
•
If the actual temperature of the soldering iron tip does not match the displayed
figure when measured accurately a compensation can be set to correct this.
•
Enter the system settings menu by pressing and holding the MENU key until the
load function has completed.
•
Enter passkey if set or the display will go straight to the system parameter settings
menu.
•
Press button “1” or “3” to select the channel you wish to adjust (MP740069 only)
and then use “UP” or “DOWN” buttons to select the Temp Offset option.
•
If the actual tip temperature is lower than the displayed temperature set a positive
matching value or a negative value if the tip temperature is higher.
•
Press “ENTER” to save the value for that channel.
TROUBLESHOOTING
CLEANING
•
Cleaning should only be done when the iron is switched off and at room
temperature.
•
The irons and station may be cleaned with a damp cloth and a small amount of
liquid detergent if necessary.
•
Never submerse the soldering iron in liquid or allow any liquid to enter the case.
•
Do not use any chemicals, abrasives or solvents that could damage the soldering
iron or station.
E-1 Thermal Fuse
Open circuit in the heating element - check connections
or replace
E-2 Sensor Alarm
Heater thermal sensor is damaged - replace heater
element
E-9 Non Compliant Tool
Connected
The iron connected is not compatible with the station