background image

7

TEMPERATURE COMPENSATION

• 

If the actual temperature of the soldering iron tip does not match the displayed 

figure when measured accurately a compensation can be set to correct this.

• 

Enter the system settings menu by pressing and holding the MENU key until the 

load function has completed.

• 

Enter passkey if set or the display will go straight to the system parameter settings 

menu.

• 

Press button “1” or “3” to select the channel you wish to adjust (MP740069 only) 

and then use “UP” or “DOWN” buttons to select the Temp Offset option.

• 

If the actual tip temperature is lower than the displayed temperature set a positive 

matching value or a negative value if the tip temperature is higher.

• 

Press “ENTER” to save the value for that channel.

TROUBLESHOOTING

CLEANING

• 

Cleaning should only be done when the iron is switched off and at room 

temperature.

• 

The irons and station may be cleaned with a damp cloth and a small amount of 

liquid detergent if necessary.

• 

Never submerse the soldering iron in liquid or allow any liquid to enter the case.

• 

Do not use any chemicals, abrasives or solvents that could damage the soldering 

iron or station.

E-1 Thermal Fuse

Open circuit in the heating element - check connections 

or replace

E-2 Sensor Alarm

Heater thermal sensor is damaged - replace heater 

element

E-9 Non Compliant Tool 

Connected

The iron connected is not compatible with the station

Summary of Contents for MP740068

Page 1: ...1 Model MP740068 Soldering Station and MP740069 Dual Soldering Station...

Page 2: ...parts before the soldering tip has cooled down completely Do not use the product near flammable items Turn the power off when this product is not in use The soldering iron must be placed on its stand...

Page 3: ...y indicating system version number the LCD will display the last set temperature for each channel 1 Channel 1 power bar product working status abnormal code 2 Channel 2 power bar product working statu...

Page 4: ...temperature setting 2 6 Quick access preset temperature setting 1 7 Soldering tool model identification 8 Set temperature display 9 Actual tip temperature display MP740068 Model Single Channel Display...

Page 5: ...er setting menu the passkey is cleared and operation is unlocked Channel Setting The tool you wish to use on the channel must be connected then press button 1 or 3 for 2 seconds to select the channel...

Page 6: ...available for users to quickly call subject to the temperature lower limit and temperature upper limit settings 8 Fix Temp After this mode is activated the tip temperature is locked at this preset val...

Page 7: ...temperature set a positive matching value or a negative value if the tip temperature is higher Press ENTER to save the value for that channel TROUBLESHOOTING CLEANING Cleaning should only be done whe...

Page 8: ...P740068 MP740069 Voltage 230V 50Hz Power 150W 200W Fuses T 2 5A 230V AC T 2 5A 230V AC Temperature Range 150o C 480o C 302o F 896o F depends on tools attached Temperature Accuracy 8o C 15o F Temperatu...