background image

 

 

 

 

 

 

 

 

 

 

 

 

 

06 - 2014 

694242A02 - Ed. 5 

 

 

 

 

 

DEUTSCHLAND - Chauvin Arnoux GmbH 

Straßburger Str. 34 - 77694 Kehl / Rhein 

Tel.: (07851) 99 26-0 - Fax: (07851) 99 26-60 

ESPAÑA - Chauvin Arnoux Ibérica S.A 

C/ Roger de Flor N° 293, Planta 1- 08025 Barcelona 

Tel.: 902 20 22 26 - Fax: 934 591 443 

ITALIA - Amra SpA 

Via Sant’Ambrogio, 23/25 - 20050 Bareggia di Macherio (MI) 

Tel.: 039 245 75 45 - Fax: 039 481 561 

ÖSTERREICH - Chauvin Arnoux GmbH 

Slamastrasse 29 / 2 / 4 - 1230 Wien 

Tel.: 01 61 61 961-0 - Fax: 01 61 61 961-61 

SCANdINAVIA - CA Mätsystem AB 

Box 4501 - SE 18304 TÄBY 

Tel.: +46 8 50 52 68 00 - Fax: +46 8 50 52 68 10 

SCHWEIZ - Chauvin Arnoux AG 

Einsiedlerstraße 535 - 8810 Horgen 

Tel.: 044 727 75 55 - Fax: 044 727 75 56 

UNITEd KINGdOM - Chauvin Arnoux Ltd 

Waldeck House - Waldeck Road - Maidenhead SL6 8BR 

Tel.: 01628 788 888 - Fax: 01628 628 099 

MIddLE EAST - Chauvin Arnoux Middle East 

P.O. BOX 60-154 - 1241 2020 JAL EL dIB (Beirut) – LEBANON 

Tel.: (01) 89 04 25 - Fax: (01) 89 04 24 

CHINA - Shanghai Pu-Jiang - Enerdis Instruments Co. Ltd 

3 F, 3 rd Building - N° 381 Xiang de Road - 200081 SHANGHAI 

Tel.: +86 21 65 21 51 96 - Fax: +86 21 65 21 61 07 

USA - Chauvin Arnoux Inc - d.b.a AEMC Instruments 

200 Foxborough Blvd. - Foxborough - MA 02035 

Tel.: (508) 698-2115 - Fax: (508) 698-2118 

 

 

- "RANGE" key 

Your multimeter has a range change function that is normally automatic but can be made 

manual. After the quantity to be measured is chosen manually ("SEL" key), the default 

mode is automatic range change: the "AUTO" message is then displayed. 

  Briefly press the "RANGE" key to change to manual mode:   the "AUTO" message is 

  then replaced by "MANU". 

  Successive brief presses are used to reach the desired range. 

  Hold the "RANGE" key down for 2 seconds to return to the automatic range change 

  mode: the "MANU" message reverts to "AUTO". 

"HOLD" key 

In the "HOLD" mode, the device freezes the display of the last value measured. 

  Pressing the "HOLD" key briefly during a measurement freezes the display:  the 

  message 

 is then displayed. 

  A second brief press on the "HOLD" key is used to return to the normal 

  measured value display refresh mode: the message 

   disappears from the 

  display unit. 

"MAX MIN" key 

The device records the maximum and minimum values of the measurements made. The 

automatic range change does not change the range when this mode is entered; if the 

maximum values exceed the display range (indicated by the "OL" message), the 

appropriate  higher range must be chosen manually before reactivating the "MAX MIN" 

mode. 

Successive brief presses on the "MAX MIN" key produce, in order, the following actions: 

  1st press: the device records and displays the maximum value 

  measured. The "AUTO" message is replaced by "MANU" and the "MAX" message is 

  displayed.  

  2nd press: the device records and displays the minimum value measured; the 

  "MAX" message is replaced by "MIN". 

  3rd press: the device records the maximum and minimum values measured 

  simultaneously; it  is the value currently measured that is displayed; the  "MAX" and 

  "MIN" messages blink simultaneously on the display unit. 

  Additional presses serve to display the values recorded  one by one by 

  reproducing the actions of the previous successive presses. 
Press the "MAX MIN" key for two seconds to exit from the mode: the "MANU", "MAX", 

and "MIN" messages are replaced by "AUTO", indicating that the device once again 

changes range automatically. 

"Hz" (Hertz) key 

When the switch is set to "VHz", a brief press on the "Hz" key displays the frequency of 

the voltage being measured. 

A 2nd press restores the display of the voltage being measured. 

 

 

 

 

 

- 4 - 

1.3   The display unit 

 

 

SCAN 

Automatic search for the quantity to be measured 

AUTO 

Automatic range change 

MANU 

Manual range change 

 

(Data Hold) Freezes the display 

 

Continuity test function 

APO 

(Auto Power Off) automatic switching off activated 

 

Diode test function 

 

 

Display of the maximum and minimum values 

 

DC measurement and display 

 

AC measurement and display 

 

Presence of hazardous voltage above 30V 

 

Display of a negative value 

 

Low battery indicator (battery must be replaced) 

Hz 

(Hertz) unit of frequency 

 

(ohm, kilo-ohm, Megohm) unit of resistance 

(Volt) unit of voltage 

 

(milliFarad, nanoFarad, microFarad) units of capacitance 

The "OL" message (OverLoad) indicates an overshoot of the measurement or display 

capacity. A display of dashes indicates waiting for the determination and selection of the 

quantity to be measured. 
 

1.4  The leads and test probes 

The multimeter is equipped with 2 leads (1 red and 1 black), each terminated by a test 

probe of the same colour. The leads and test probes are not detachable (they are 

permanently connected) and, when not in use, can be stowed in the compartments 

provided for them on the right side of the device. 

The tips of the test probes (once taken out of their compartments by pressing on them 

with a finger), allow  voltage, resistance, continuity, diode test, and capacitance 

measurements. 

The test probes have physical guards that show the operator where the hand grip part 

ends, beyond which the fingers must not be placed. 

 

- 5 - 

2.  USE 

2.1  Commissioning  

Place the batteries supplied with the device as follows: 
1.  Using a cross-headed screwdriver, unscrew the screw of the compartment cover on 

  the back of the housing and open the cover. 
2. Place the 2 batteries in their compartment, with the correct polarities. 
3. Close the cover and screw it back to the housing. 

 

 

2.2 

Starting up and check of operation 

We recommend performing this procedure at the time of commissioning and, if the device 

is used only occasionally, each time it is used. 

  Hold the "HOLD" key down and switch the instrument on by turning the switch from 

  "OFF" to "Ω". 

  Keep the "HOLD" key pressed and check that the various   symbols and segments 

  are correctly displayed (the 1st digit on the left may be a "6" or an "8"). 

  Releasing the "HOLD" key restores the normal display for the function chosen. 

  If the device is set to the resistance measurement function ("Ω"), check that  the 

  display indicates "A.P.O" (for auto power off), "SCAN" (for automatic search for the 

  quantity to be measured), dashes "---" (to indicate search in progress). 

  Withdraw the two leads from their compartment and establish a good contact between 

  the  metallic parts of the two test probes; the value measured and displayed must 
  change from "---" to "0.0Ω" accompanied by the message "

" (the value displayed 

  may not be exactly zero, but must remain very close to zero). 

  The instrument is operational when the various states described above have been 

  checked and are correct. The rotary switch can then be set to the desired function or 

  to "OFF" to switch the instrument off. 

2.3 

Deactivating Auto Power Off 

  In order to extend the life of the batteries, the device switches itself off automatically 

approximately 10 minutes after it is switched on if no key or change of function has been 

activated.  

 

- 6 - 

 