Instruction Sheet

Subject: Installations Instructions

Air Compressor Kits

 

1 of 9

 

Part Number 020006402  12/2014

MULTIPLEX 

2100 FUTURE, SELLERSBURG, IN 47172

800-367-4233 

WWW.MANITOWOCBEVERAGE.COM/US

Importar

Read the following warnings before beginning an 

installation. Failure to do so may result in possible death 

or serious injury.

n

Wtoaiag

Tp Avpid Seoipus ajuoy

DO

 Adhere to all National and Local Plumbing and 

Electrical Safety Codes.

DO

 Turn “off” incoming electrical service switches when 

servicing, installing, or repairing equipment.

DO

 Check that all flare fittings on the carbonation 

tank(s) are tight. This check should be performed with a 

wrench to ensure a quality seal.

DO

 Inspect pressure on regulators before starting up 

equipment.

DO

 Protect eyes when working around refrigerants.

DO

 Use caution when handling metal surface edges of 

all equipment.

DO

 Handle CO

2

 cylinders and gauges with care. Secure 

cylinders properly against abrasion.

DO

 Store CO

2

 cylinder(s) in well ventilated areas.

DO NOT

 Throw or drop a CO

2

 cylinder. Secure the 

cylinder(s) in an upright position with a chain.

DO NOT

 Connect the CO

2

 cylinder(s) directly to the 

product container. Doing so will result in an explosion 

causing possible death or injury. It is best to connect the 

CO

2

 cylinder(s) to a regulator(s).

DO NOT

 Store CO

2

 cylinders in temperature above 125°F 

(51.7°C) near furnaces, radiator or sources of heat.

DO NOT

 Release CO

2

 gas from old cylinder.

DO NOT

 Touch refrigeration lines inside units. Some 

may exceed temperatures of 200°F (93.3°C).

Importar

Water pipe connections and fixtures directly connected 

to a potable water supply shall be sized, installed and 

maintained in accordance with Federal, State, and Local 

codes.

n

Wtoaiag

Dtageo pf Elecroic Shpck

Disconnect and lock out all electrical power sources 

before performing service or maintenance on this 

machine — except when electrical tests are being 

performed by qualified service personnel.

Summary of Contents for 00212053

Page 1: ...le CO2 cylinders and gauges with care Secure cylinders properly against abrasion DO Store CO2 cylinder s in well ventilated areas DO NOT Throw or drop a CO2 cylinder Secure the cylinder s in an uprigh...

Page 2: ...sary do not connect the grounding wire to a flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire Check with a qualifi...

Page 3: ...2 section of 1 4 tubing connected at bottom side of change over valve Route and connect the remaining end of tubing to the syrup tank supply manifold refer to figure above 3 Locate the 12 ft x 1 4 EV...

Page 4: ...remaining end of the air line to the inlet and onto the outlet of the low pressure regulator Route and connect the remaining end of the tubing to the inlet side of the air filter assembly 4 Connect on...

Page 5: ...ply Manifold Air CO2 Change over Valve Retaining Ring Handle and Screw Model 37KX Manifolds 3 Locate the air CO2 change over valve supplied with the air pump installation kit P N 212508 Provided with...

Page 6: ...ifold See figure above 5 Locate the 4 1 2 11 4 cm section of 1 4 6 35 mm tubing and connect to the bottom side of the air CO2 change over valve Route and connect the remaining end of tubing to the syr...

Page 7: ...ave a ground wire connecting terminal 2 Locate the loose end of the power cord attached to the kit All three wires are stripped to 1 2 length from the end 3 Connect all three wires to plug using the 1...

Page 8: ...AIR COMPRESSOR TANK 1 Remove and discard the four 4 old well nuts from the stand s air compressor mounting brackets and replace with four 4 new well nuts provided in kit refer to figure 2 Position the...

Page 9: ...are provided for this purpose 2 Insert the rubber pads into the holes in the bracket that match the holes in the air pump 3 Position the air pump on the pads and screw in the bolts with washers Tight...