1.  Determine location where the air pump will be 

installed.

NOTE: Install the air compressor wall mount bracket (if 

applicable).

2.  Install the air compressor in its final location with 

proper hardware.

3.  Mount the low pressure regulator (packed separately) 

to a convenient location. Attach the 10 ft x 1/4" ID air 

line (provided with air compressor) to the air pump 

outlet fitting. Route and connect the remaining end of 

the air line to the inlet and onto the outlet of the low 

pressure regulator. Route and connect the remaining 

end of the tubing to the inlet side of the air filter 

assembly.

4.  Connect one (1) end of the remaining section of the air 

line to the outlet side of the air filter assembly. Route 

and connect the opposite end of the air line to the 

incoming air connection on the left side of the blender.

5.  Attach the 10 ft x 3/8" ID drain line to the tank drain 

fitting and route opposite end to floor drain.

6.  Close tank outlet valve and plug air compressor into a 

120 VAC outlet (domestic).

NOTE: Allow tank to fill completely and shut “off”. 

Compressor should shut “off” at approximately 70 psi 

(4.8 bar). Compressor will start up when tank pressure drops 

to approximately 50 psi (3.1 bar).

7.  Open tank outlet valve and adjust air compressor 

regulator to 40 psi (2.8 bar).

Summary of Contents for 00212053

Page 1: ...le CO2 cylinders and gauges with care Secure cylinders properly against abrasion DO Store CO2 cylinder s in well ventilated areas DO NOT Throw or drop a CO2 cylinder Secure the cylinder s in an uprigh...

Page 2: ...sary do not connect the grounding wire to a flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire Check with a qualifi...

Page 3: ...2 section of 1 4 tubing connected at bottom side of change over valve Route and connect the remaining end of tubing to the syrup tank supply manifold refer to figure above 3 Locate the 12 ft x 1 4 EV...

Page 4: ...remaining end of the air line to the inlet and onto the outlet of the low pressure regulator Route and connect the remaining end of the tubing to the inlet side of the air filter assembly 4 Connect on...

Page 5: ...ply Manifold Air CO2 Change over Valve Retaining Ring Handle and Screw Model 37KX Manifolds 3 Locate the air CO2 change over valve supplied with the air pump installation kit P N 212508 Provided with...

Page 6: ...ifold See figure above 5 Locate the 4 1 2 11 4 cm section of 1 4 6 35 mm tubing and connect to the bottom side of the air CO2 change over valve Route and connect the remaining end of tubing to the syr...

Page 7: ...ave a ground wire connecting terminal 2 Locate the loose end of the power cord attached to the kit All three wires are stripped to 1 2 length from the end 3 Connect all three wires to plug using the 1...

Page 8: ...AIR COMPRESSOR TANK 1 Remove and discard the four 4 old well nuts from the stand s air compressor mounting brackets and replace with four 4 new well nuts provided in kit refer to figure 2 Position the...

Page 9: ...are provided for this purpose 2 Insert the rubber pads into the holes in the bracket that match the holes in the air pump 3 Position the air pump on the pads and screw in the bolts with washers Tight...

Reviews: