Part Number 020006402  12/2014

Air Compressor Kits 

Aio PuIm & Ttak wirh Chtage-pveo Vtlve & DuIm Vtlve Kir — P.N. 00212145 (220V), 

P.N. 00214971 (220V)

These instructions cover the installation of the 220V/50Hz 

Multiplex Air Pump kit. This kit is designed to be used 

with Model 37KX and Model 44KX. The air pump must be 

mounted to the support stand with a minimum of a 6-inch 

clearance.

1.  Mount air compressor mounting channel to left side of 

stand in the third hole down with two 1/4-20 nuts and 

screws provided with kit. (See figure below)

2.  Install pump/tank assembly to stand and mounting 

channel with four 1/4-20 nuts and screws provided 

with kit. (See figure below)

1/4" ID Tube 

(Use 3 Ft.)

Air Pump Tank 

Compression 

Elbow

Shutoff 

Valve

Air Compressor

Mounting 

Channel

8 ft. (2.44 m) Length" of 

Tubing to Floor Drain

Pump Tank 

Assembly

Stand

Dump Valve

asrtlltripa

NSTALLATON OF MODEL 37KX REFRGERATON UNT

1.  Shut off main CO

2

 supply to refrigeration unit.

2.  Open the CO

2

 control panel door on the refrigeration 

unit and locate the 3/8" O.D. (9.5 mm) white 

polyethylene tubing that is routed between the 

carbonator tank CO

2

 supply manifold and the syrup 

tank CO

2

 supply manifold (see figure below). Remove 

and discard this section of tubing.

12' x 114" 

(3.86 m x 6.35 mm)  

Eva Tubing

To Outlet 

Fitting of Air 

Pump Tank

Carbonator 

Tank CO

2

 Supply 

Manifold

Remove and 

Discard

Syrup Tank 

CO

2

 Supply 

Manifold

Air/CO

2

  

Change-over Valve

Retaining Ring, 

Handle, and Screw

Mpdel 37KX Mtaifplds

3.  Locate the air/CO

2

 change-over valve supplied with 

the air pump installation kit (P.N. 212508 Provided with 

Stand). Remove the change-over valve handle, screw, 

and retainer ring. Install the change-over valve in the 

hole provided in the control panel marked “Air/CO

2

 

Change-over Valve”. Replace the retainer ring, valve 

handle, and screw. (See figure above)

4.  Attach the upper 3/8" O.D. (9.5 mm) white polyethylene 

tubing of the CO

2

 change-over valve to the carbonator 

tank CO

2

 supply manifold. Attach the lower 3/8" O.D. 

(9.5 mm) white polyethylene tubing of the CO

2

 change-

over valve to the syrup tank CO

2

 supply manifold. Use 

compression nuts supplied with kit. (See figure above)

NOTE: Tum air/CO

2

 change-over valve handle to the “CO

2

” 

position.

5.  Locate the 12' x 1/4" EVA (3.66 meters x 6.35 mm) 

tubing supplied with air compressor. Attach the end 

of this line assembly with the swivel nut to the outlet 

fitting of the air compressor tank. Neatly route tubing 

under the stand top, up through the opening in lower 

right end of control panel and attach the opposite end 

of this line assembly to the 1/4" (6.35 mm) barb elbow 

of the air/CO

2

 change-over valve previously installed in 

the control panel. Trim excess line as necessary. Use two 

tab clamps to hold tube on stem. (See figure above)

6.  Locate the dump valve supplied with air compressor. 

Mount the dump valve with #10-32 self-tapping screws 

provided with kit to lower left cross channel of support 

stand. Use holes provided in channel. (See Installation 

figure)

Summary of Contents for 00212053

Page 1: ...le CO2 cylinders and gauges with care Secure cylinders properly against abrasion DO Store CO2 cylinder s in well ventilated areas DO NOT Throw or drop a CO2 cylinder Secure the cylinder s in an uprigh...

Page 2: ...sary do not connect the grounding wire to a flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire Check with a qualifi...

Page 3: ...2 section of 1 4 tubing connected at bottom side of change over valve Route and connect the remaining end of tubing to the syrup tank supply manifold refer to figure above 3 Locate the 12 ft x 1 4 EV...

Page 4: ...remaining end of the air line to the inlet and onto the outlet of the low pressure regulator Route and connect the remaining end of the tubing to the inlet side of the air filter assembly 4 Connect on...

Page 5: ...ply Manifold Air CO2 Change over Valve Retaining Ring Handle and Screw Model 37KX Manifolds 3 Locate the air CO2 change over valve supplied with the air pump installation kit P N 212508 Provided with...

Page 6: ...ifold See figure above 5 Locate the 4 1 2 11 4 cm section of 1 4 6 35 mm tubing and connect to the bottom side of the air CO2 change over valve Route and connect the remaining end of tubing to the syr...

Page 7: ...ave a ground wire connecting terminal 2 Locate the loose end of the power cord attached to the kit All three wires are stripped to 1 2 length from the end 3 Connect all three wires to plug using the 1...

Page 8: ...AIR COMPRESSOR TANK 1 Remove and discard the four 4 old well nuts from the stand s air compressor mounting brackets and replace with four 4 new well nuts provided in kit refer to figure 2 Position the...

Page 9: ...are provided for this purpose 2 Insert the rubber pads into the holes in the bracket that match the holes in the air pump 3 Position the air pump on the pads and screw in the bolts with washers Tight...

Reviews: