background image

 

7 of 9 

 

Part Number 020006402  12/2014

Air Compressor Kits 

CONNECTNG THE AR PUMP TO THE STAND OUTLET 

BOX

n

Wtoaiag

Before proceeding with this installation, make sure the 

power to this box is disconnected.

1.  Locate the outlet box under the stand. Open the cover 

of the outlet box.

2.  Remove one of the 1/2" dia. knock-outs on the side or 

bottom of the box.

3.  Route the loose end of pump cord and terminals 

through the Romex connector, the box wall opening, 

and then the Romex connector lock-nut. Tighten the 

connector and lock-nut securely against the box wall.

4.  Connect the brown wire to the open terminal available 

on the switch labeled “Air compressor” as shown on the 

wiring diagram below. Connect the blue wire to the 

other two blue wires inside the box that are already 

connected with wire-nut terminal.

5.  “Ground” the pump to the unit using the ground screw 

available on box and the green wire. 

6.  Replace the box cover and tighten the holding screws 

securely.

CONNECTNG THE AR PUMP TO THE WALL OUTLET

An appropriate 3-wire power receptacle must be available 

within 6 feet from the intended operating location of the air 

pump kit. A locally furnished plug must be attached to the 

power cord in order to be accepted by the local electrical 

receptacle.

1.  Locate a 3-wire plug. This plug (not furnished with kit) 

must have a ground-wire connecting terminal.

2.  Locate the loose end of the power cord attached to the 

kit. All three wires are stripped to 1/2" length from the 

end.

3.  Connect all three wires to plug using the 1/2" stripped 

ends or any other terminal requirements. Different 

plugs and terminals may require different stripped 

lengths.

4.  Check cord and plug connection for any loose or bare 

wires.

Electrical Conduit

11.5" (29.2 cm) Line

Dump Valve

220V to Air 

Compressor

220V to Water 

Booster

220V

220V

Air Pump

Wiring Diagram 

for Junction Box

n

Wtoaiag

To avoid the risk of electrical shock, the installer must 

check the following: 
This pump kit must be grounded. In the event of an 

electrical short circuit, grounding reduces the risk of 

electrical shock by providing an escape wire for the 

electrical current. This product is equipped with a 

grounding-type cord. To reduce the risk of electrical 

shock, be certain that the plug and cord are securely 

assembled and that they are used only with a properly 

grounded receptacle. Check with a qualified electrician 

or serviceman if the grounding instructions are not 

completely understood.
Do not use an extension cord or an adapter plug with 

this equipment. Do not splice the furnished power cord 

to a locally supplied cord. If another power cord must 

be used, completely replace the existing cord with the 

new one. Proceed with the electric connection of the 

stand outlet box to the refrigeration unit electrical box 

using the stand installation instructions packed with the 

stand.

Summary of Contents for 00212053

Page 1: ...le CO2 cylinders and gauges with care Secure cylinders properly against abrasion DO Store CO2 cylinder s in well ventilated areas DO NOT Throw or drop a CO2 cylinder Secure the cylinder s in an uprigh...

Page 2: ...sary do not connect the grounding wire to a flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire Check with a qualifi...

Page 3: ...2 section of 1 4 tubing connected at bottom side of change over valve Route and connect the remaining end of tubing to the syrup tank supply manifold refer to figure above 3 Locate the 12 ft x 1 4 EV...

Page 4: ...remaining end of the air line to the inlet and onto the outlet of the low pressure regulator Route and connect the remaining end of the tubing to the inlet side of the air filter assembly 4 Connect on...

Page 5: ...ply Manifold Air CO2 Change over Valve Retaining Ring Handle and Screw Model 37KX Manifolds 3 Locate the air CO2 change over valve supplied with the air pump installation kit P N 212508 Provided with...

Page 6: ...ifold See figure above 5 Locate the 4 1 2 11 4 cm section of 1 4 6 35 mm tubing and connect to the bottom side of the air CO2 change over valve Route and connect the remaining end of tubing to the syr...

Page 7: ...ave a ground wire connecting terminal 2 Locate the loose end of the power cord attached to the kit All three wires are stripped to 1 2 length from the end 3 Connect all three wires to plug using the 1...

Page 8: ...AIR COMPRESSOR TANK 1 Remove and discard the four 4 old well nuts from the stand s air compressor mounting brackets and replace with four 4 new well nuts provided in kit refer to figure 2 Position the...

Page 9: ...are provided for this purpose 2 Insert the rubber pads into the holes in the bracket that match the holes in the air pump 3 Position the air pump on the pads and screw in the bolts with washers Tight...