DAC7000 SERIES GENERATORS • OPERATION AND PARTS MANUAL — REV. #0 (02/15/16) — PAGE 23
INSPECTION/SETUP
GENERAL INSPECTION PRIOR TO OPERATION
Ground Power Tools
When using power tools or electrical equipment requireing
AC power from the generator, make sure power tool cord
has a ground pin or is double insulated as shown in Figure 6.
Figure 6. Ground Pin
Extension Cable
When electric power is to be provided to various tools or
loads at some distance from the generator, extension cords
are normally used. Cables should be sized to allow for
distance in length and amperage so that the voltage drop
between the generator and point of use (load) is held to a
minimum. Use the cable selection chart (Table 4) as a guide
for selecting proper cable size.
Circuit Breakers
ALWAYS
place the
main
, and
GFCI
circuit breakers in the
OFF
position prior to starting the engine.
NOTICE
Double-insulated power tools and small appliances
have specially insulated housings that eliminate the
need for a ground. These types of double-insulated
power cords are designed so that no part of the device
will be electrically live even if the internal insulation fails.
DANGER
NEVER
use power tools or equipment that do not
have a ground capability, the possibility exists of
electrocution, electrical shock or burn, which can cause
severe bodily harm or even
DEATH
!
Table 4. Cable Selection (60 Hz, Single Phase Operation)
Current In
Amperes
Load In Watts
Maximum Allowable Cable Length
120 Volts
240 Volts
#10 Wire
#12 Wire
#14 Wire
#16 Wire
2.5
300
600
1000 ft.
600 ft.
375 ft.
250 ft.
5
600
1200
500 ft.
300 ft.
200 ft.
125 ft.
7.5
900
1800
350 ft.
200 ft.
125 ft.
100 ft.
10
1200
2400
250 ft.
150 ft.
100 ft.
15
1800
3600
150 ft.
100 ft.
65 ft.
20
2400
4800
125 ft.
75 ft.
50 ft.
CAUTION
: Equipment damage can result from low voltage.
Summary of Contents for DAC7000SS
Page 15: ...DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 PAGE 15 NOTE...
Page 59: ...DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 PAGE 59 NOTES...
Page 64: ...PAGE 64 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 GENERATOR ASSY...
Page 66: ...PAGE 66 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 CONTROL PANEL ASSY...
Page 74: ...PAGE 74 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 BATTERY ASSY...
Page 76: ...PAGE 76 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 MUFFLER ASSY...
Page 78: ...PAGE 78 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 FUEL TANK ASSY...
Page 82: ...PAGE 82 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 ENCLOSURE ASSY...
Page 86: ...PAGE 86 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 RUBBER SEALS ASSY...
Page 171: ...DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 PAGE 171 NOTES...