PAGE 28 — DAC7000 SERIES GENERATORS• OPERATION AND PARTS MANUAL — REV. #0 (02/15/16)
OPERATION
Before Starting the Engine
1. Open the cabinet door and turn the fuel cock lever
(Figure 14) to the “ON” position.
Figure 14. Fuel Cock Lever (ON)
2.
NEVER
operate the generator with the doors
open
(Figure 15). Operation with the doors open may cause
insufficient cooling of the unit, and engine damage may
result. Close the doors for normal operation.
Figure 15. Generator Doors
CAUTION
The engine’s exhaust contains harmful emissions.
ALWAYS have adequate ventilation
when operating.
Direct exhaust away from nearby personnel.
WARNING
NEVER
manually start the engine with the
main
or
GFCI
circuit breakers in the
ON
(closed) position.
IDLE CONTROL
0
0
0
0
0
HOURS
ON
OFF
WHISPERWATT
7KW AC
Model DA-7000SS
7000 WATT
DIESEL POW
ERED AC GEN
ERATOR
STARTER SWIT
CH
RUN
HEAT
START
STOP
HOUR METER
120/240V
25A
25A
120/240V
25A
25A
AC VOLTMET
ER
AC CIRCUIT
BREAKER
IDLE CONTROL
0
0
0
0
0
HOURS
ON
OFF
WHISPERW
ATT
7KW AC
Model DA-7000SS
7000 WATT
DIESEL POW
ERED AC GEN
ERATOR
STARTER SWI
TCH
RUN
HEAT
START
STOP
HOUR METER
120/240V
25A
25A
120/240V
25A
25A
AC VOLTMET
ER
AC CIRCUIT
BREAKER
WHISPERW
ATT
7000
CORRECT
3.
NEVER
start the engine with the main circuit breaker
in the
ON
position. Always place circuit breaker (Figure 16)
in the
OFF
position before starting.
Figure 16. Main Circuit Breaker (OFF)
4.
NEVER
start the engine with the
GFCI
circuit breaker
in the
ON
position. Always place circuit breaker (Figure
17) in the
OFF
position before starting the engine.
Figure 17. GFCI Circuit Breaker (OFF)
Starting the Engine
1. Insert the key into the starter switch (Figure 18) and
turn it to the “
RUN
” position. Check to see that the oil
pressure and charge Lights on the "Warning Lamp
Unit Display " are lit. If either light is not lit, check the
system and wiring (refer to the Engine Operation
Manual).
Figure 18. Starter Switch
2. Turn the ignition key to the
HEAT
position. When the
preheat light goes off, turn the key to the
START
position to start the engine. As soon as the engine
starts, release the key. The key will automatically return
to the
RUN
position.
3. During winter or when the surrounding air temperature
is cold, in situations where a load start is required, turn
the key to the
HEAT
position, you must wait until the
preheat light goes off.
OFF
OFF
25A
25A
Summary of Contents for DAC7000SS
Page 15: ...DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 PAGE 15 NOTE...
Page 59: ...DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 PAGE 59 NOTES...
Page 64: ...PAGE 64 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 GENERATOR ASSY...
Page 66: ...PAGE 66 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 CONTROL PANEL ASSY...
Page 74: ...PAGE 74 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 BATTERY ASSY...
Page 76: ...PAGE 76 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 MUFFLER ASSY...
Page 78: ...PAGE 78 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 FUEL TANK ASSY...
Page 82: ...PAGE 82 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 ENCLOSURE ASSY...
Page 86: ...PAGE 86 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 RUBBER SEALS ASSY...
Page 171: ...DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 PAGE 171 NOTES...