DAC7000 SERIES GENERATORS • OPERATION AND PARTS MANUAL — REV. #0 (02/15/16) — PAGE 33
MAINTENANCE
Maintenance
Perform the scheduled maintenance procedures as defined
by Table 8 and below:
Engine Oil
Every 100 hours:
Change engine oil after the first 50 hours
of operation and 100 hours thereafter. Always check the
crankcase oil level prior to each use, or when the fuel tank
is filled. Insufficient oil may cause severe engine damage.
Make sure generator is level when checking oil level. The
oil level must be between the two notches on the dipstick
as shown in Figure 8.
1. Remove engine oil drain plug located at the bottom of
the generator enclosure (Figure 9) and drain oil from
crankcase.For best results drain oil while engine is
warm. Reinstall oil drain plug, and add engine oil as
specified in Table 5. Crankcase oil capacity is 2.64 qts.
(2.5 liters).
Figure 29. Engine Oil Drain Plug
Oil Filter Cartridge
Every 200 hours:
Replace the engine oil filter cartridge
after every 200 hours of operation.
1. Clean oil filter mounting base, and coat oil filter seal
(Figure 30) with clean engine oil.
Figure 30. Oil Filter Cartridge
2. Screw on new oil filter by hand until seal contacts the
filter mounting base. Install drain bolt with sealing
washer and hand tighten.
3. Replace engine oil with recommended type oil as listed
in Table 5. For engine oil capacity, see Table 2 (engine
specifications). Fill to upper limit as shown in Figure 8.
Engine Air Cleaner
Every 50 hours:
The air cleaner employed on the
KUBOTA Z482 series engines is a dry type,
NEVER
apply oil to it. If generator is used in severe dusty areas
service air cleaner element more frequently.
1. Release the air cleaner retaining clamps (Figure 31)
and remove the air cleaner element.
Figure 31. Air Cleaner
2. Wipe the inside of the air cleaner with a clamp cloth and
remove all dust and debris that may have accumulated
inside air cleaner body.
3. Tap the edge of element lightly to allow heavy dust
build-up to fall off.
4. Tap the paper filter element (Figure 31) several times
on a hard surface to remove dirt, or blow compressed
air [not exceeding 99 psi (686 kPa, 2.1 kgf/cm2)]
through the filter element from from the inside while
turning the element.
NEVER
brush off dirt. Brushing
will force dirt into the fibers.
5. Replace the filter element once a year or every six
cleanings or if it is excessively dirty
NOTICE
When installing the oil filter, coat rubber seal with a
small amount of lubricant (motor oil).
DO NOT
over-
tighten cartridge. Hand tighten only.
Summary of Contents for DAC7000SS
Page 15: ...DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 PAGE 15 NOTE...
Page 59: ...DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 PAGE 59 NOTES...
Page 64: ...PAGE 64 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 GENERATOR ASSY...
Page 66: ...PAGE 66 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 CONTROL PANEL ASSY...
Page 74: ...PAGE 74 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 BATTERY ASSY...
Page 76: ...PAGE 76 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 MUFFLER ASSY...
Page 78: ...PAGE 78 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 FUEL TANK ASSY...
Page 82: ...PAGE 82 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 ENCLOSURE ASSY...
Page 86: ...PAGE 86 DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 RUBBER SEALS ASSY...
Page 171: ...DAC7000 SERIES GENERATORS OPERATION AND PARTS MANUAL REV 0 02 15 16 PAGE 171 NOTES...