PAGE 28 — MAYCO LS600 PUMP — OPERATION AND PARTS MANUAL — REV. #4 (9/15/11)
HOSE LUBRICATION
Before pumping, it is necessary to lubricate the hose.
This procedure prevents separation and blockages in the
hose.
Inspect the lines at all times to prevent problems.
Before concrete is discharged into the hopper, it is sug-
gested that 3 to 4 gallons of water be sprayed into the
hopper, followed by approximately 5 gallons of a creamy
cement and water slurry (1/2 bag of cement to 5 gallons of
water).
PRIMING THE PUMP WITH SLURRY MIXTURE
It is
CRITICAL
to the successful operation of a concrete
pump that the manifold and all delivery hoses, pipes and
elbows are coated with a film of lubrication
BEFORE
you
attempt to pump concrete.
Failure to properly prepare the pump and system will result
in a “dry pack” of concrete, blocking the shuttle valve tube
or delivery line.
1. Connect the entire delivery system to the pump. Pour
5 gallons of water and a bag of raw cement into the
hopper.
2. Place the
Direction Control Switch
to the
REVERSE
position (Figure 25). This will mix the water and cement
into slurry.
3. Mix the slurry to the consistency of a smooth batter.
4. Position the first ready-mix truck at the hopper. Check
the concrete.
DO NOT
discharge concrete into hopper
at this time.
5. Place the
Direction Control Switch
in the
FORWARD
position. This will start the flow of the slurry to the
hoses.
6. Keep the slurry flowing until most of it is pumped out.
However, make sure that some slurry is left on the
hopper when concrete is first discharged from the ready-
mix truck.
LS600 PUMP — OPERATION
Getting the concrete to flow through the hose
at the start of the pumping cycle can be one
of the most critical operations of the pour.
PUMPING
1. Place the
Pumping Control Switch
to the
LOCAL
position (Figure 26) for normal pumping operation.
2. Slide the
Volume Control Switch
(Figure 27) to the
right to increase the volume to approximately
10
strokes per minute
. Sliding the volume control to the
left will
decrease
pump volume.
A
thumping
sound (cylinder stroke) should be heard.
The thumping sound represents the number of strokes
per minute (volume) of the pump.
3. Scroll through the
Digital Readout Screen
with the
scroll switch to go to Screen 7 (Figure 28). This screen
will show the volume in strokes per minute.
Safety glasses
MUST
be worn at
all times when operating the pump.
Failure to follow safety guidelines
can result in
serious
injury.
WARNING - SAFETY GLASSES
A well-planned location of the pump and
routing of the hose before starting a pour
may save subsequent moves throughout
the job.
FORWARD
REVERSE
Figure 25. Direction Control Switch (REVERSE)
LOCAL
REMOTE
CENTER
OFF
Figure 26. Pumping Control Switch (LOCAL)
Figure 27. Volume Control
INCREASE
VOLUME
DECREASE
VOLUME
+
_
THROTTLE ON
STROKES: 100
STROKES/MIN 10.0
YDS/HR 0.0
7
Figure 28. Strokes Per Minute Display
Summary of Contents for MAYCO LS600
Page 3: ...MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 PAGE 3 NOTES...
Page 11: ...MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 PAGE 11 NOTES...
Page 81: ...MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 PAGE 81 NOTES...
Page 92: ...PAGE 92 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP FRAME ASSY...
Page 96: ...PAGE 96 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP BRAKE LINE ASSY...
Page 98: ...PAGE 98 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP BRAKE LIGHT ASSY...
Page 102: ...PAGE 102 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP BATTERY ASSY...
Page 104: ...PAGE 104 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP HOPPER ASSY...
Page 116: ...PAGE 116 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP FUELTANK ASSY...
Page 120: ...PAGE 120 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP ACCUMULATOR ASSY...
Page 130: ...PAGE 130 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP ENGINE ASSY...
Page 134: ...PAGE 134 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP THROTTLE ASSY...
Page 138: ...PAGE 138 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP HYD PUMP ASSY...