DCA-400SSK — PARTS AND OPERATION MANUAL (STD)— REV. #3 (09/17/01) — PAGE 45
DCA-400SSK — PRE-SETUP
Battery Cable Installation
ALWAYS
be sure the battery cables (Figure 30) are properly
connected to the battery terminals as shown below. The
RED
RED
RED
RED
RED cable is connected to the positive terminal of the battery,
and the
BLACK
cable is connected to the negative terminal
of the battery.
When connecting battery do the following:
1.
DO NOT
connect the battery cables to the battery
terminals when the Off/Manual/Auto
Off/Manual/Auto
Off/Manual/Auto
Off/Manual/Auto
Off/Manual/Auto switch is in either
the manual or auto position (ON).
ALWAYS
make sure
that the Off/Manual/Auto switch is in the OFF position
when connecting the battery.
2. Place a small amount of grease around both battery
terminals. This will ensure a good connection and will
help prevent corrosion around the battery terminals.
CAUTION
:
Inadequate battery connections may cause
poor starting of the generator, and create
other malfunctions.
Wiring
Inspect the entire generator for bad or worn electrical wiring
or connections. If any wiring or connections are exposed
(insulation missing) replace wiring immediately.
Piping and Hose Connection
Inspect all piping, oil hose, and fuel hose connections for
wear and tightness. Tighten all hose clamps and check hoses
for leaks.
If any hose (fuel or oil) lines are defective replace them
immediately.
Figure 30. Battery Connections
If the battery cable is connected
incorrectly, electrical damage to the
generator will occur. Pay close attention
to the polarity of the battery when
connecting the battery.
CAUTION
:
Battery
This unit is of negative ground
DO NOT
connect in reverse.
Always maintain battery fluid level between the specified
marks. Battery life will be shortened, if the fluid level is not
properly maintained. Add only distilled water when
replenishment is necessary.
The battery is sufficiently charged if the specific gravity of
the battery fluid is 1.28 (at 68
°
F). If the specific gravity
should fall to 1.245 or lower, it indicates the battery is
discharged and needs to be recharged or replaced.
Check to see whether the battery cables are loose. Poor
contact may result in poor starting or malfunctions. Always
keep the terminals firmly tightened. Coating the terminals
with a thin film of grease will help inhibit corrosion.
Summary of Contents for Power WHISPERWATT DCA-400SSK
Page 2: ...PAGE 2 DCA 400SSK PARTS AND OPERATION MANUAL STD REV 3 09 17 01...
Page 27: ...DCA 400SSK PARTS AND OPERATION MANUAL STD REV 3 09 17 01 PAGE 27 NOTE PAGE...
Page 53: ...DCA 400SSK PARTS AND OPERATION MANUAL STD REV 3 09 17 01 PAGE 53 NOTE PAGE...
Page 59: ...DCA 400SSK PARTS AND OPERATION MANUAL STD REV 3 09 17 01 PAGE 59 NOTE PAGE...
Page 104: ...PAGE 104 DCA 400SSK PARTS AND OPERATION MANUAL STD REV 3 09 17 01 DCA 400SSK RUBBER SEAL ASSY...
Page 113: ...DCA 400SSK PARTS AND OPERATION MANUAL STD REV 3 09 17 01 PAGE 113 NOTE PAGE...